| 15594.1 |
Custom Clad (A) |
Double Hung 37" x 76" Insulated Glass (5/16" PVB Lam in - 1/8" out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-60 Other: |
Installation Instructions FL15594_R19_II_D009737 (15594.1) - Custom Clad Wood Double Hung 37.5x76 DP50-60 FBC Installs_3-24-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-04001 - 15594.1 Calcs R1 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.2 |
Custom Clad (B) |
Double Hung 41" x 76" Insulated Glass (5/16" PVB Lam in - 1/8" out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: |
Installation Instructions FL15594_R19_II_D009737 (15594.2) - Custom Clad Wood Double Hung 41.5x76 DP50 FBC Installs_3-24-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-04002 - 15594.2 Calcs R1 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.3 |
Custom Clad Epic |
Double Hung 56" x 83" Insulated Glass (5/16" PVB Lam in - 1/8" Annealed out) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Exterior lite above 30 feet must be tempered. |
Installation Instructions FL15594_R19_II_D008682 (15594.3) - Custom Epic Clad Wood Double Hung 56.375x83.25 DP55-70 FBC Installs_3-20-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-04003 - 15594.3 Calcs R1 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.4 |
Custom Clad Epic |
Double Hung 41" x 116" Insulated Glass (5/16" PVB Lam in - 1/8" Annealed out) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Exterior lite above 30 feet must be tempered. |
Installation Instructions FL15594_R19_II_D008682 (15594.4) - Custom Epic Clad Wood Double Hung 41.375x116.375 DP55-70 FBC Installs_3-20-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-04004 - 15594.4 Calcs R1 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.5 |
Custom Clad Epic |
Double Hung 49" x 96" Insulated Glass (5/16" PVB Lam in - 1/8" Annealed out) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Exterior lite above 30 feet must be tempered. |
Installation Instructions FL15594_R19_II_D008682 (15594.5) - Custom Epic Clad Wood Double Hung 49.375x96.25 DP55-70 FBC Installs_3-20-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-04005 - 15594.5 Calcs R1 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.6 |
Custom Clad Epic |
Double Hung 66" x 70" Insulated Glass (5/16" PVB Lam in - 1/8" Annelaed out) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Exterior lite above 30 feet must be tempered. |
Installation Instructions FL15594_R19_II_D008682 (15594.6) - Custom Epic Clad Wood Double Hung 66.375x70.25 DP55-65 FBC Installs_3-20-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-04006 - 15594.6 Calcs R1 DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.7 |
Siteline (W-5500) Clad Wood |
Double Hung Tilt 33 3/8" x 80" Insulated Glass (9/32" PVB Lam in - 1/8" Annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-65 Other: |
Installation Instructions FL15594_R19_II_D016050 (20118.1) - Siteline (W-5500) Clad Wood Double Hung Tilt 33x80 DP50-65 WZ3 FBC Installs_9-25-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-12005 - 20118.1 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 15594.8 |
Siteline (W-5500) Clad Wood |
Double Hung 45" x 80" Insulated Glass (9/32" PVB Lam in - 1/8" Annealed out) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-65 Other: |
Installation Instructions FL15594_R19_II_D016050 (20118.2) - Siteline (W-5500) Clad Wood Double Hung Tilt 45x80 DP50-65 WZ3 FBC Installs_9-25-25 DSS.pdf Verified By: Micah Swartz 93573 Created by Independent Third Party: Yes Evaluation Reports FL15594_R19_AE_SCE 25-12006 - 20118.2 Calcs DSS.pdf Created by Independent Third Party: Yes |