Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL15594-R21
Application Type Revision
Code Version 2026
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Jeld-Wen
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(541) 850-2650
FBC1@jeldwen.com
 
Authorized Signature Rylee Fricks
FBC1@jeldwen.com
 
Technical Representative JELD-WEN Customer Experience
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls, OR 97601
(800) 535-3936
CustomerServiceUS@jeldwen.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Double Hung
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Micah Schwartz
Florida License PE-93573
Quality Assurance Entity Window and Door Manufacturers Association-QA
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL15594_R21_COI_COI Letter - DSS.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402022
ASTM E18862019
ASTM E19962020
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 07/16/2026
Date Validated 08/20/2026
Date Pending FBC Approval 08/27/2026
Date Approved 10/13/2026
 
Summary of Products
FL # Model, Number or Name Description
15594.1 Custom Clad (A) Double Hung 37" x 76" Insulated Glass (5/16" PVB Lam in - 1/8" out)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-60
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D009737 (15594.1) - Custom Clad Wood Double Hung 37.5x76 DP50-60 FBC Installs_3-24-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-04001 - 15594.1 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
15594.2 Custom Clad (B) Double Hung 41" x 76" Insulated Glass (5/16" PVB Lam in - 1/8" out)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D009737 (15594.2) - Custom Clad Wood Double Hung 41.5x76 DP50 FBC Installs_3-24-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-04002 - 15594.2 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
15594.3 Custom Clad Epic Double Hung 56" x 83" Insulated Glass (5/16" PVB Lam in - 1/8" Annealed out)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: Exterior lite above 30 feet must be tempered.Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D008682 (15594.3) - Custom Epic Clad Wood Double Hung 56.375x83.25 DP55-70 FBC Installs_3-20-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-04003 - 15594.3 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
15594.4 Custom Clad Epic Double Hung 41" x 116" Insulated Glass (5/16" PVB Lam in - 1/8" Annealed out)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: Exterior lite above 30 feet must be tempered.Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D008682 (15594.4) - Custom Epic Clad Wood Double Hung 41.375x116.375 DP55-70 FBC Installs_3-20-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-04004 - 15594.4 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
15594.5 Custom Clad Epic Double Hung 49" x 96" Insulated Glass (5/16" PVB Lam in - 1/8" Annealed out)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: Exterior lite above 30 feet must be tempered.Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D008682 (15594.5) - Custom Epic Clad Wood Double Hung 49.375x96.25 DP55-70 FBC Installs_3-20-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-04005 - 15594.5 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
15594.6 Custom Clad Epic Double Hung 66" x 70" Insulated Glass (5/16" PVB Lam in - 1/8" Annelaed out)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Exterior lite above 30 feet must be tempered.Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D008682 (15594.6) - Custom Epic Clad Wood Double Hung 66.375x70.25 DP55-65 FBC Installs_3-20-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-04006 - 15594.6 Calcs R1 DSS.pdf
 Created by Independent Third Party: Yes
15594.7 Siteline (W-5500) Clad Wood Double Hung Tilt 33 3/8" x 80" Insulated Glass (9/32" PVB Lam in - 1/8" Annealed out)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-65
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D016050 (20118.1) - Siteline (W-5500) Clad Wood Double Hung Tilt 33x80 DP50-65 WZ3 FBC Installs_9-25-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-12005 - 20118.1 Calcs DSS.pdf
 Created by Independent Third Party: Yes
15594.8 Siteline (W-5500) Clad Wood Double Hung 45" x 80" Insulated Glass (9/32" PVB Lam in - 1/8" Annealed out)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-65
 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. 
Installation Instructions
 FL15594_R21_II_D016050 (20118.2) - Siteline (W-5500) Clad Wood Double Hung Tilt 45x80 DP50-65 WZ3 FBC Installs_9-25-25 DSS.pdf
 Verified By: Micah Swartz 93573
 Created by Independent Third Party: Yes
Evaluation Reports
 FL15594_R21_AE_SCE 25-12006 - 20118.2 Calcs DSS.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 