Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL11383-R8
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Powers Steel, Inc.
Address/Phone/Email 4118 E. Elwood St.
Phoenix, AZ 85040
(888) 525-0108   Ext 360
PCurry@powerssteel.com
 
Authorized Signature Paul Curry
PCurry@powerssteel.com
 
Technical Representative Steve Schaub
Address/Phone/Email 5800 E. Thomas Rd.
Phoenix, AZ 85251
sws@seconsultants.com
 
Quality Assurance Representative Mindy Roland
Address/Phone/Email 4118 E. Elwood St.
Phoenix, FL 85040
(602) 437-1160
qc@powerssteel.com
 
Category Structural Components
Subcategory Products Introduced as a Result of New Technology
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Steven Schaub
Florida License PE-60509
Quality Assurance Entity Timber Products Inspection, Inc.
Quality Assurance Contract Expiration Date 01/24/2026
Validated By SAMUEL A. GREENBERG, P.E,
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11383_R8_COI_RELEASE LETTER PowerBox8 2024 FL11383.pdf
 
Referenced Standard and Year (of Standard)
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
SECTION 2103
SECTION 2104
SECTION 2107
SECTION 2108
SECTION 2210
 
 
 
Product Approval Method Method 2 Option B
 
Date Submitted 01/30/2024
Date Validated 02/09/2024
Date Pending FBC Approval 02/14/2024
Date Approved 04/16/2024
 
Summary of Products
FL # Model, Number or Name Description
11383.1 PowerBOX8 Lintels Powers Steel Lintels are field assembled consisting of preformed steel lintels combined with brick or concrete masonry units, grout, and steel reinforcing bars.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: N/A
 Other: The lintels shall not exceed the allowable design loads and spans shown in this report. The lintels shall not be used in a fire rated assembly unless a test report documenting fire resistance is submitted to the building official. A proper barrier of 10 MIL thickness or to maintain a minimum 1/4 inch spacing between corrosive lumber and the steel lintel. Not for use in HVHZ Miami or Broward Counties at this time.
Installation Instructions
 FL11383_R8_II_PowerBox8 NOTES DETAILS 2024 FL11383.pdf
 Verified By: Steven W. Schaub PE - 60509
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11383_R8_AE_EVALUATION LETTER PowerBox8 2024 FL11383.pdf
 FL11383_R8_AE_PowerBox8 TABLES NOTES DETAILS 2024 FL11383.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 