|
|
| 8153.1 |
1. Series 9000 Single Hung Window (HVHZ)(Impact) |
Series 9000 Single Hung Window (HVHZ)(Impact) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See Installation Instructions and Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. |
Certification Agency Certificate FL8153_R14_C_CAC_NI011578.01-R3.pdf FL8153_R14_C_CAC_NI011578.03-R4.pdf FL8153_R14_C_CAC_NI011578-R3.pdf FL8153_R14_C_CAC_NI013164-R5.pdf FL8153_R14_C_CAC_NI015229.01-R1.pdf FL8153_R14_C_CAC_NI015229.02-R1.pdf FL8153_R14_C_CAC_NI015229-R1.pdf Quality Assurance Contract Expiration Date 10/31/2026 Installation Instructions FL8153_R14_II_SWD053 SS 2023-11-29.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL8153_R14_AE_PER8948 SS 2023-11-29.pdf Created by Independent Third Party: Yes |
|
|
| 8153.2 |
2. Series 9000 Single Hung Window (Non-HVHZ)(Impact) |
Series 9000 Single Hung Window (Non-HVHZ)(Impact) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See Installation Instructions and Evaluation Report for allowable design pressures, sizes, installation requirements and limits of use. |
Certification Agency Certificate FL8153_R14_C_CAC_NI006735.03-R1.pdf FL8153_R14_C_CAC_NI006735.04-R1.pdf FL8153_R14_C_CAC_NI011578.03-R4.pdf FL8153_R14_C_CAC_NI013164-R5.pdf FL8153_R14_C_CAC_NI015229.01-R1.pdf FL8153_R14_C_CAC_NI015229.02-R1.pdf FL8153_R14_C_CAC_NI015229-R1.pdf Quality Assurance Contract Expiration Date 10/31/2026 Installation Instructions FL8153_R14_II_SWD054 SS 2023-11-29.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL8153_R14_AE_PER8949 SS 2023-11-29.pdf Created by Independent Third Party: Yes |
|
|
| 8153.3 |
3. 6000 Security Series Vinyl Single Hung Window (Non-HVHZ)(Non-Impact) |
6000 Security Series Vinyl Single Hung Window (Non-HVHZ)(Non-Impact) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: See Installation Instructions and Evaluation Report for allowable sizes, installation requirements and limits of use. |
Certification Agency Certificate FL8153_R14_C_CAC_NI015270-R1.pdf Quality Assurance Contract Expiration Date 10/31/2026 Installation Instructions FL8153_R14_II_SWD057 SS 2023-11-29.pdf Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL8153_R14_AE_PER8950 SS 2023-11-29.pdf Created by Independent Third Party: Yes |