Product Approval Menu > Application Detail
 
FL # FL30339-R5
Application Type Revision
Code Version 2026
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Quicken Steel
Address/Phone/Email 188 Georgia Pacific Dr
Claxton, GA 304171
(912) 549-4050
james@quickensteel.com
 
Authorized Signature Coleman James
james@quickensteel.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report David Eng
Florida License PE-81377
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2030
Validated By James R Wally, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL30339_R5_COI_26ga_Q-STRIP 100_plywood.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/05/2026
Date Validated 08/06/2026
Date Pending FBC Approval 08/11/2026
Date Approved 10/13/2026
 
Summary of Products
FL # Model, Number or Name Description
30339.1 01: Q-STRIP 100 26ga (min) 1" nail strip on 15/32" (min) plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116
 Other: 116psf with fastener at ±5" oc and sealant, 71psf with fastener at ±10" oc
Installation Instructions
 FL30339_R5_II_26ga_Q-STRIP 100_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_26ga_Q-STRIP 100_plywood.pdf
 Created by Independent Third Party: Yes
30339.2 02: QuickRib PR-5 26ga (min) rib panel over 15/32" plywood (min)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123.5
 Other: 123.5 psf with 9"-9" fastener pattern at 12" oc, 82.25 psf with 9"-9" fastener pattern at 24" oc
Installation Instructions
 FL30339_R5_II_26ga_Quickrib_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_26ga_Quickrib_plywood.pdf
 Created by Independent Third Party: Yes
30339.3 03: Q-LOCK 175 26ga (min) 1.75" snap lock clipped system over 15/32" plywood (min)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: 93.5psf with clips at 12" oc, 63.5psf with clips at 16" oc
Installation Instructions
 FL30339_R5_II_26ga_Q-LOCK 175_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_26ga_Q-LOCK 175_plywood.pdf
 Created by Independent Third Party: Yes
30339.4 04: QuickRib PR-5 29ga (min) rib panel over 15/32" plywood (min), fastener in the rib
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123.5
 Other: 123.5psf with 9"-9" fastener pattern at 12" oc, 56psf with 9"-9" fastener pattern at 24" oc
Installation Instructions
 FL30339_R5_II_29ga_Quickrib_plywood_rib.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_29ga_Quickrib_plywood_rib.pdf
 Created by Independent Third Party: Yes
30339.5 05: QuickRib PR-5 29ga (min) rib panel over 1x4 battens (min) on 15/32" plywood (min)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-131
 Other: 131 psf with 9"-9" fastener pattern at 12" oc, 78.5psf with 9"-9" fastener pattern at 24" oc
Installation Instructions
 FL30339_R5_II_29ga_Quickrib_1x4.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_29ga_Quickrib_1x4.pdf
 Created by Independent Third Party: Yes
30339.6 06: QuickRib PR-5 29ga (min) rib panel over 15/32" plywood (min)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: 93.5psf with 9"-9" fastener pattern at 12" oc, 56psf with 9"-9" fastener pattern at 24" oc
Installation Instructions
 FL30339_R5_II_29ga_Quickrib_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_29ga_Quickrib_plywood.pdf
 Created by Independent Third Party: Yes
30339.7 07: 5V Crimp 26ga (min) 5V panel over 15/32" plywood (min)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5
 Other: 108.5 psf with 12"-12" fastener pattern at 12" oc
Installation Instructions
 FL30339_R5_II_26ga_5V_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_26ga_5V_plywood.pdf
 Created by Independent Third Party: Yes
30339.8 08: PBU 26ga (min) PBU panel over 15/32" plywood (min)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-131
 Other: See evaluation report.
Installation Instructions
 FL30339_R5_II_26ga_PBU_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL30339_R5_AE_26ga_PBU_plywood.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 