| 30314.1 |
1 NewTechWood Wall Cladding Panel US09 System |
Exterior Wall Panel System made of Plastic Composites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +150/-150 Other: ASD Pressure Rating of +/- 150 psf at 20" subframe spacing on concrete and concrete block or 16" subframe spacing on wood. See Section 7 of Product Evaluation Report for additional Limitations and Conditions of Use. |
Installation Instructions FL30314_R4_II_PED Drwg 23-110 NewTechWood America.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL30314_R4_AE_PER Drwg 23-110 NewTechWood America.pdf Created by Independent Third Party: Yes |
|
|
| 30314.2 |
2 NewTechWood Decorative European Wall Cladding Panel UH46 System |
Exterior Wall Panel System made of Plastic Composites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +varies/-varies Other: ASD Pressure Rating of +/- 150 psf with maximum 20" subframe spacing on concrete and concrete block or 16" maximum subframe spacing on wood when subframe is installed vertically or 20" maximum subframe spacing on wood when subframe is installed horizontally.
See Sheet 28 of PED # 23-111 for additional limitations and anchor spacing for lower ASD Pressure Rating of 112.5 psf.
See Section 7 of Product Evaluation Report for additional Limitations and Conditions of Use. |
Installation Instructions FL30314_R4_II_PED Drwg 23-111 NewTechWood America.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL30314_R4_AE_PER Drwg 23-111 NewTechWood America.pdf Created by Independent Third Party: Yes |
|
|
| 30314.3 |
3 NewTechWood Decorative European Exterior Wall Cladding Panels UH58 (7") & UH68 (6") |
Decorative Exterior Composite Wall Panels. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +varies/-varies Other: ASD Pressure Rating of +/- 140 psf with maximum 16" subframe spacing on concrete, concrete block or wood. See Sheet 24 of PED #24-050 for anchor spacing limitations. See Section 7 of Product Evaluation Report for additional Limitations and Conditions of Use. |
Installation Instructions FL30314_R4_II_PED Dwg 24-050 - NewTechWood.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL30314_R4_AE_PER Dwg 24-050 NewTechWood.pdf Created by Independent Third Party: Yes |