FL # FL30452-R4
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Weather Shield Mfg., Inc.
Address/Phone/Email 829 N. 8th Street
Medford, WI 54451
(715) 748-2100   Ext 3933
nora.thums@weathershield.com
 
Authorized Signature Valerie Bach
val.bach@weathershield.com
 
Technical Representative Valerie Bach
Address/Phone/Email 829 N. Eighth Street
Medford, WI 54451
(715) 748-2100   Ext 3932
val.bach@weathershield.com
 
Quality Assurance Representative Andrew Haumschild
Address/Phone/Email 642 South Whelen Ave.
Medford, WI 54451
(715) 748-2100   Ext 4310
andrew.haumschild@weathershield.com
 
Category Windows
Subcategory Casement
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A440-112011
ASTM E18862013
ASTM E19962014
TAS201/202/2031994
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/21/2023
Date Validated 01/02/2024
Date Pending FBC Approval
Date Approved 01/06/2024
Date Revised 07/31/2026
 
Summary of Products
FL # Model, Number or Name Description
30452.1 1210 Premium Impact Coastal Casement Roundtop 35-1/2" x 83-1/2" R-PG55; 902mm x 2121mm (35.5 in width/83.5 in height) Type-C
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 25mm (1”) thick laminated insulated glass comprised of 3.9mm (5/32”) annealed / 9.5mm (3/8”) Endur spacer / 3.9mm (5/32”) / .090” PVB / 3.9mm (5/32”) annealed glass. Glass complies with E1300 requirements.
Certification Agency Certificate
 FL30452_R4_C_CAC_449-H-013.106, .107, .109 1210 Premium Coastal Roundtop Casement.pdf
Quality Assurance Contract Expiration Date
 06/04/2029
Installation Instructions
 FL30452_R4_II_1210 Round Top Casement Nail Fin-Through Frame-Installation Clips.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
30452.2 1210 Twin Premium Impact Coastal Casement Eyebrow 35-1/2" x 83-1/2" (2-wide) R-PG55; 902mm x 2121mm (35.5 in trib. width/83.5 in span) Type-MA
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 25mm (1”) thick laminated insulated glass comprised of 3.9mm (5/32”) annealed / 9.5mm (3/8”) Endur spacer / 3.9mm (5/32”) / .090” PVB / 3.9mm (5/32”) annealed glass. Glass complies with E1300 requirements.
Certification Agency Certificate
 FL30452_R4_C_CAC_449-H-013.102, .103, .108 1210 Premium Coastal Eyebrow Casement.pdf
Quality Assurance Contract Expiration Date
 07/31/2029
Installation Instructions
 FL30452_R4_II_1210 Two Wide Arch Top Casement -- Nail Fin-Through Frame-Installation Clips.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
30452.3 8217 Premium Alum Clad Pushout Casement 41-1/2" x 83-1/2" R-PG50- 1054mm x 2121mm (41-1/2" x 83-1/2")- C
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: 19mm (3/4") insulated glass comprised of two 3.9mm (5/32”) thick clear annealed glass. Glass complies with E1300 requirements.
Certification Agency Certificate
 FL30452_R4_C_CAC_449-H-084.04 8217 Prem Push out Casement.pdf
Quality Assurance Contract Expiration Date
 12/19/2028
Installation Instructions
 FL30452_R4_II_8217 Pushout Casement Nail Fin.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
30452.4 8218 Premium Alum Clad French Casement 71-1/16" x 71-1/2" LC-PG50- 1805mm x 1816mm (71-1/16" x 71-1/2"")- C
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: 19mm (3/4") insulated glass comprised of two 3.1mm (1/8”) thick clear annealed glass. Glass complies with E1300 requirements.
Certification Agency Certificate
 FL30452_R4_C_CAC_449-H-019.05 8218 Prem French Casement.pdf
Quality Assurance Contract Expiration Date
 03/18/2029
Installation Instructions
 FL30452_R4_II_8218 French Csmt Nail Fin.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 