| 30444.1 |
Tuff-Rib |
Max 36" wide, min 29 ga. steel through fastened panel over plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: UL Construction No. 560. Design uplift pressure with fasteners spaced @ 24" o.c. = 52.5 psf. The required design wind loads shall be determined for each project. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code. For installation in areas within 3000 ft. of a saltwater coastline, fasteners are corrosion resistant as per FBC 2026 Section 1711. |
Certification Agency Certificate FL30444_R3_C_CAC_UL560.pdf Quality Assurance Contract Expiration Date 12/31/2029 Installation Instructions FL30444_R3_II_UL560.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |