| 30443.1 |
A - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 37.5" x 81.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-90 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.17-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X IS FBC 37x82 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5132 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.2 |
B - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 37.5" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-85 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.05-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X IS FBC 37x98 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5121 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.3 |
C - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 43.5" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-85 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X IS FBC 43x98 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5134 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.4 |
D - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 43.5" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-85 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.02-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X IS FBC 43x98B SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5119 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.5 |
E - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 43.5" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-85 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.04-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X IS FBC 43x98A SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5118 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.6 |
F - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 43.5" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-85 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.03-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X IS FBC 43x98C SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5117 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.7 |
G - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 37.5" x 80.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-80 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.18-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X OS FBC 37x81 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5133 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.8 |
H - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 37.5" x 96.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-75 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.06-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X OS FBC 37x97 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5120 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.9 |
I - Architectural Fiberglass |
Outswing Door 1 Panel X Opaque 43.5" x 96.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +75/-75 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.01-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP OPQ X OS FBC 43x97 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5116 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.10 |
J - Architectural Fiberglass |
Inswing Door 1 Panel X Glazed 37.5" x 82" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-70 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.16-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FG IMP GLZ X IS FBC 37x82 SS 2019-09-11.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5131 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.11 |
K - Architectural Fiberglass |
Outswing Door 1 Panel X Opaque 37.5" x 80.75" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-70 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.15-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP GLZ X OS FBC 37x81 SS 2018-01-10.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5130 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.12 |
L - Architectural Fiberglass |
Inswing Door 2 Panel XX Glazed 74" x 80.75" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.14-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_D014722 (30443.12) - Architectural Fiberglass Swinging Door Inswing 2 Panel XX 74x80 DP50 G-WZ3 FBC_9-30-26 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_SCE 26-09019 - 30443.12 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 30443.13 |
M - Architectural Fiberglass |
Inswing Door 2 Panel XX Glazed 74" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.09-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_D014722 (30443.13) - Architectural Fiberglass Swinging Door Inswing 2 Panel XX 74x98 DP50 G-WZ3 FBC_9-30-26 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_SCE 26-09020 - 30443.13 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 30443.14 |
N - Architectural Fiberglass |
Outswing Door 2 Panel XX Glazed 74" x 96.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.10-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP GLZ XX OS FBC 74x97 SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5125 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.15 |
O - Architectural Fiberglass |
Inswing Door 1 Panel with Sidelites OXO Glazed 112.5" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.11-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_D014774 (30443.15) - Architectural Fiberglass Swinging Door Inswing 3 Panel OXO 113x98 DP50 G-WZ3 FBC_9-30-26 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_SCE 26-09021 - 30443.15 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 30443.16 |
P - Architectural Fiberglass |
Inswing Door 2 Panel with Sidelites OXXO Glazed 149.25" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.07-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_D014775 (30443.16) - Architectural Fiberglass Swinging Door Inswing 4 Panel OXXO 149x98 DP50 G-WZ3 FBC_9-30-26 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_SCE 26-09022 - 30443.16 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 30443.17 |
Q - Architectural Fiberglass |
Inswing Door 2 Panel with Sidelites OXXO Opaque 149.25" x 97.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +35/-40 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.12-R3.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP GLZ OXXO IS FBC 149x96A SS 2017-12-08.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5127 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.18 |
R - Architectural Fiberglass |
Outswing Door 2 Panel with Sidelites OXXO Glazed 149.25" x 96.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.08-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP GLZ CHS OXXO OS FBC 149.25x96.875 SS 2018-05-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5123 SS 2018-08-07.pdf Created by Independent Third Party: Yes |
|
|
| 30443.19 |
S - Architectural Fiberglass |
Outswing Door 2 Panel with Sidelites OXXO Glazed 149.25" x 96.88" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL30443_R8_C_CAC_NI013685.13-R4.pdf Quality Assurance Contract Expiration Date 04/30/2032 Installation Instructions FL30443_R8_II_ARCH FB IMP GLZ B2B OXXO OS FBC 149.25x96.875 SS 2018-05-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL30443_R8_AE_PER5128 SS 2018-08-07.pdf Created by Independent Third Party: Yes |