Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL17668-R3
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer OLDCASTLE BUILDING ENVELOPE
Address/Phone/Email 803 Airport Road
Terrell, TX 75150
(972) 551-6232
knolan@obe.com
 
Authorized Signature Kristin Nolan
knolan@obe.com
 
Technical Representative Bill Lang
Address/Phone/Email 803 Airport Rd
Terrell, TX 75150
(972) 551-6164
blang@obe.com
 
Quality Assurance Representative Marilee Murphy
Address/Phone/Email 8655 Elm Fair Blvd
Tampa, FL 33610
(813) 663-0949
mmurphy@obe.com
 
Category Windows
Subcategory Projected
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report WALTER A. TILLIT, JR.
Florida License PE-44167
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2026
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL17668_R3_COI_COI DRWG 23-088 OldCastle Bldg Env.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E13002009
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/15/2023
Date Validated 08/15/2023
Date Pending FBC Approval 08/18/2023
Date Approved 10/17/2023
Date Revised 09/01/2026
 
Summary of Products
FL # Model, Number or Name Description
17668.1 SERIES ZS-2750 PROJECT OUT ALUMINUM WINDOW SYSTEM SERIES ZS-2750 PROJECT OUT ALUMINUM WINDOW SYSTEM, LARGE MISSILE IMPACT RESISTANT
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-60
 Other: Large Missile Impact Resistant, see General Note No. 2, Sheet 1 of installation drawing 23-088. ASD Pressure rating: +/- 60 psf at 55-1/16" max frame width. For applications over 30 ft. above grade use safety glazing for exterior lite per FBC Section 2411.1.11.
Installation Instructions
 FL17668_R3_II_PED DRWG 23-088 OldCastle Bldg Env.pdf
 Verified By: WALTER A. TILLIT, JR. P.E. PE-44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL17668_R3_AE_PER DRWG 23-088 OldCastle Bldg Env.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex