| 1763.1 |
Advantage Panel 26 Ga. |
26 Ga. Advantage Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -82.25 psf at 9”-9”-9”-9” Fastener Pattern at 24” o.c. Fastener Spacing. -123.5 psf at 9”-9”-9”-9” Fastener Pattern at 12” o.c. Fastener Spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL1763_R5_II_26 Ga. Advantage Roof Panel over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL1763_R5_AE_26 Ga. Advantage Roof Panel over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 1763.2 |
Permatile Panel 26 Ga. |
26 Ga. Permatile Roof Panel over ½” Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.0PSF Other: -74.8 psf at 14”-14” Fastener Pattern at 14” o.c. Fastener Spacing. -161.0 psf at 7”-7”-7”-7” Fastener Pattern at 14” o.c. Fastener Spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL1763_R5_II_26 Ga. Permatile Roof Panel over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL1763_R5_AE_26 Ga. Permatile Roof Panel over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 1763.3 |
Permatile Panel Aluminum 0.030" |
0.030" Aluminum Permatile Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -104.8 psf at 14”-14” Fastener Pattern at 12” o.c. Fastener Spacing. -153.5 psf at 7"-7"-7"-7” Fastener Pattern at 12” o.c. Fastener Spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL1763_R5_II_Aluminum Permatile Roof Panel over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL1763_R5_AE_Aluminum Permatile Roof Panel over Plywood HVHZ.pdf Created by Independent Third Party: Yes |