Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL17694-R8
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Weather Shield Mfg., Inc.
Address/Phone/Email 829 N. 8th Street
Medford, WI 54451
(715) 748-2100   Ext 3933
nora.thums@weathershield.com
 
Authorized Signature Nora Thums
nora.thums@weathershield.com
 
Technical Representative Valerie Bach
Address/Phone/Email 829 N. Eighth Street
Medford, WI 54451
(715) 748-2100   Ext 3932
val.bach@weathershield.com
 
Quality Assurance Representative Andrew Haumschild
Address/Phone/Email 642 South Whelen Ave.
Medford, WI 54451
(715) 748-2100   Ext 4310
andrew.haumschild@weathershield.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 450-102010
AAMA/WDMA/CSA 101/I.S.2/A440-082008
AAMA/WDMA/CSA 101/I.S.2/A440-112011
ASTM E 18862005
ASTM E 19962012
TAS 201, TAS 202, TAS 2031994
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL17694_R8_Equiv_tb-equivilancy-memo_nafs_201.pdf
FL17694_R8_Equiv_TB-Revised_Equivalency_ASTM_.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/17/2024
Date Validated 12/31/2024
Date Pending FBC Approval
Date Approved 01/02/2025
Date Revised 05/30/2025
 
Summary of Products
FL # Model, Number or Name Description
17694.1 1209 Premium Impact Casement Picture CW-PG65-FW 1054x1969 (42x78)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-85
 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_1209 Premium Casement Picture.pdf
Quality Assurance Contract Expiration Date
 06/02/2025
Installation Instructions
 FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.2 1209 Premium Impact Picture Window CW-PG55-FW 1816x2121 (72x84)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 23/32" Cardinal "LG" laminated glass comprised of (5/16") annealed / .090" SGP / (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-018.18,20,21 1209 Premium Impact Casement Picture , Single Glaze 8_10_26.pdf
Quality Assurance Contract Expiration Date
 08/10/2026
Installation Instructions
 FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.3 1209 Premium Impact Picture Window CW-PG55-FW 1816x2121 (72x84)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 9/16" Cardinal "LG" laminated glass comprised of (1/4") annealed / .090" SGP / (1/4") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-018.18,20,21 1209 Premium Impact Casement Picture , Single Glaze 8_10_26.pdf
Quality Assurance Contract Expiration Date
 08/10/2026
Installation Instructions
 FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.4 1209 Premium Impact Picture Window CW-PG55-FW 1816x2121 (72x84)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 23/32" Cardinal "LG" laminated glass comprised of (5/16") annealed / .090" SGP / (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-018.18,20,21 1209 Premium Impact Casement Picture , Single Glaze 8_10_26.pdf
Quality Assurance Contract Expiration Date
 08/10/2026
Installation Instructions
 FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.5 1209 Premium Impact Picture Window (Laminated Monolithic) CW-PG55-FW 2121x1054 (84x42)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-70
 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_1209 Premium Impact Picture Window (Laminated Monolithic) (Report ESP018804P-1673).pdf
Quality Assurance Contract Expiration Date
 04/15/2025
Installation Instructions
 FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.6 1209 Premium Impact Picture Window, Single Glazed CW-PG55-FW 1829x2134 (72x84)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-018.07_.10 1209 Premium Impact Picture Window, Single Glaze.pdf
Quality Assurance Contract Expiration Date
 03/18/2026
Installation Instructions
 FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.7 1210 Casement Picture IG Impact CW-PG55-FW 1816x2121 (71.5x83.5)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: (1”) thick Cardinal insulated glass comprised of 6.3mm (1/4”) tempered / 7.9mm (5/16”) Endur spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) heat strengthened. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_1210 Casement Picture IG.pdf
Quality Assurance Contract Expiration Date
 09/16/2025
Installation Instructions
 FL17694_R8_II_27845.05-1002 - 1210 Casement Pict Alternate Install Instr.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.8 1210 Casement Picture Impact CW-PG55-FW 1816x2121 (71.5x83.5)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 1”) thick Cardinal insulated glass comprised of 3.9mm (5/32”) tempered / 9.5mm (3/8”) Endur Spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_FL17694_R5_C_CAC_1210 Casement Picture IG.pdf
Quality Assurance Contract Expiration Date
 09/16/2025
Installation Instructions
 FL17694_R8_II_27845.05-1002 - 1210 Casement Pict Alternate Install Instr.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.9 1210 Casement Picture Impact CW-PG55-FW 1816x2121 (71.5x83.5)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 1”) thick Cardinal insulated glass comprised of 3.9mm (5/32”) tempered / 9.5mm (3/8”) Endur Spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_1210 Casement Picture IG.pdf
Quality Assurance Contract Expiration Date
 09/16/2025
Installation Instructions
 FL17694_R8_II_27845.05-1002 - 1210 Casement Pict Alternate Install Instr.pdf
 FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.10 1309 Premium Impact Direct Set Mullion CW-PG55-MA 3632x2121 (143x84)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 7/16" Cardinal "LG" laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-005.17, .20,.21,.51 Impact Direct Set 1310 2-wide.pdf
Quality Assurance Contract Expiration Date
 06/15/2025
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 FL17694_R8_II_WS Nail Fin Install.pdf
 FL17694_R8_II_WS Through Jamb Install.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.11 1309 Premium Impact Direct Set, Single Glazed CW-PG65-FW 1143x3048 (45x120) Nail Fin Install
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-85
 Other: 17/32" Cardinal "LG" laminated glass comprised of (1/4") annealed / .090" SGP / (1/4") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-005.24,26,27 Impact Direct Set 1309 9_16_26.pdf
Quality Assurance Contract Expiration Date
 09/16/2026
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.12 1309 Premium Impact Direct Set, Single Glazed CW-PG65-FW 1143x3048 (45x120) Through Jamb Installation
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-85
 Other: 23/32" Cardinal "LG" laminated glass comprised of (5/16") annealed / .090" SGP / (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-005.24,26,27 Impact Direct Set 1309 9_16_26.pdf
Quality Assurance Contract Expiration Date
 09/16/2026
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.13 1310 Premium Impact Direct Set Mullion CW-PG55-MA 3632x2121 (143x84)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: 1" insulated glass comprised 6.3mm (1/4") tempered / 8mm (5/16") Super Spacer / 3.9mm (5/32") / .090" SGP / 3.9 (5/32") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-005.17, .20,.21,.51 Impact Direct Set 1310 2-wide.pdf
Quality Assurance Contract Expiration Date
 06/15/2025
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 FL17694_R8_II_WS Nail Fin Install.pdf
 FL17694_R8_II_WS Through Jamb Install.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.14 1310 Premium Impact Direct Set, Dual Glazed CW-PG65-FW 1143x3048 (45x120) Fin Installation
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-85
 Other: 1-1/4" insulated glass comprised of 6mm (1/4") tempered / 9.5mm (3/8") Super Spacer / 8mm (5/16") / .090" SGP / 8mm (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-005.28,30,31 Impact Direct Set 1309 9_13_26.pdf
Quality Assurance Contract Expiration Date
 09/13/2026
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.15 1310 Premium Impact Direct Set, Dual Glazed CW-PG65-FW 1143x3048 (45x120) Clip Install
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-85
 Other: 1-1/8" insulated glass comprised of 6mm (1/4") tempered / 9.5mm (3/8") Endur Spacer / 6mm (1/4") / .090" SGP / 6mm (1/4") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_1310 Premium Impact Direct Set, Dual Glazed (Report ESP019206P-1690.1).pdf
Quality Assurance Contract Expiration Date
 03/13/2025
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.16 1310 Premium Impact Direct Set, Dual Glazed CW-PG65-FW 1143x3048 (45x120) Through Jamb Install
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-85
 Other: 1-1/8" insulated glass comprised of 6mm (1/4") tempered / 9.5mm (3/8") Endur Spacer / 6mm (1/4") / .090" SGP / 6mm (1/4") heat strengthened glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_449-H-005.28,30,31 Impact Direct Set 1309 9_13_26.pdf
Quality Assurance Contract Expiration Date
 09/13/2026
Installation Instructions
 FL17694_R8_II_85-7849-14-Alt-2023.pdf
 FL17694_R8_II_EvalReport-1310-DS-2023.pdf
 FL17694_R8_II_WS Direct Set Clip Install.pdf
 FL17694_R8_II_WS Nail Fin Install.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.17 Premium Coastal Double Hung Tilt Transom (1110) SG CW-PG55-1207x1054 (48x42)-FW
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: utilized single nominal (11/32”) thick Cardinal “LG” laminated glass comprised of (1/8”) annealed / .090” PVB / (1/8”) annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_Premium Coastal Double Hung Tilt Transom (1110) SG.pdf
Quality Assurance Contract Expiration Date
 07/28/2025
Installation Instructions
 FL17694_R8_II_1110-1111 Ind DH Transom Installation Instruction -- Nail Fin-Thru Jamb-Installation Clips 1.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17694.18 Premium Coastal Double Hung Tilt Transom (1111) IG CW-PG55-1207x1054 (48x42)-FW
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-70
 Other: Utilized nominal 19mm (3/4") thick insulated glass comprised of 3.9mm (5/32”) tempered / 8.0mm (5/16”) Endur Spacer / 2.3mm (3/32”) / .090” PVB / 2.3mm (3/32”) annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Certification Agency Certificate
 FL17694_R8_C_CAC_Premium Coastal Double Hung Tilt Transom (1111) IG.pdf
Quality Assurance Contract Expiration Date
 07/28/2025
Installation Instructions
 FL17694_R8_II_1110-1111 Ind DH Transom Installation Instruction -- Nail Fin-Thru Jamb-Installation Clips 1.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex