| 17694.1 |
1209 Premium Impact Casement Picture |
CW-PG65-FW 1054x1969 (42x78) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_1209 Premium Casement Picture.pdf Quality Assurance Contract Expiration Date 06/02/2025 Installation Instructions FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.2 |
1209 Premium Impact Picture Window |
CW-PG55-FW 1816x2121 (72x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 23/32" Cardinal "LG" laminated glass comprised of (5/16") annealed / .090" SGP / (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-018.18,20,21 1209 Premium Impact Casement Picture , Single Glaze 8_10_26.pdf Quality Assurance Contract Expiration Date 08/10/2026 Installation Instructions FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.3 |
1209 Premium Impact Picture Window |
CW-PG55-FW 1816x2121 (72x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 9/16" Cardinal "LG" laminated glass comprised of (1/4") annealed / .090" SGP / (1/4") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-018.18,20,21 1209 Premium Impact Casement Picture , Single Glaze 8_10_26.pdf Quality Assurance Contract Expiration Date 08/10/2026 Installation Instructions FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.4 |
1209 Premium Impact Picture Window |
CW-PG55-FW 1816x2121 (72x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 23/32" Cardinal "LG" laminated glass comprised of (5/16") annealed / .090" SGP / (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-018.18,20,21 1209 Premium Impact Casement Picture , Single Glaze 8_10_26.pdf Quality Assurance Contract Expiration Date 08/10/2026 Installation Instructions FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.5 |
1209 Premium Impact Picture Window (Laminated Monolithic) |
CW-PG55-FW 2121x1054 (84x42) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-70 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_1209 Premium Impact Picture Window (Laminated Monolithic) (Report ESP018804P-1673).pdf Quality Assurance Contract Expiration Date 04/15/2025 Installation Instructions FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.6 |
1209 Premium Impact Picture Window, Single Glazed |
CW-PG55-FW 1829x2134 (72x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-018.07_.10 1209 Premium Impact Picture Window, Single Glaze.pdf Quality Assurance Contract Expiration Date 03/18/2026 Installation Instructions FL17694_R8_II_27845.05-1001 - 1209 Fixed Casement Installation Drawings.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.7 |
1210 Casement Picture IG Impact |
CW-PG55-FW 1816x2121 (71.5x83.5) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: (1”) thick Cardinal insulated glass comprised of 6.3mm (1/4”) tempered / 7.9mm (5/16”)
Endur spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) heat strengthened. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_1210 Casement Picture IG.pdf Quality Assurance Contract Expiration Date 09/16/2025 Installation Instructions FL17694_R8_II_27845.05-1002 - 1210 Casement Pict Alternate Install Instr.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.8 |
1210 Casement Picture Impact |
CW-PG55-FW 1816x2121 (71.5x83.5) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1”) thick Cardinal insulated glass comprised of 3.9mm
(5/32”) tempered / 9.5mm (3/8”) Endur Spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_FL17694_R5_C_CAC_1210 Casement Picture IG.pdf Quality Assurance Contract Expiration Date 09/16/2025 Installation Instructions FL17694_R8_II_27845.05-1002 - 1210 Casement Pict Alternate Install Instr.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.9 |
1210 Casement Picture Impact |
CW-PG55-FW 1816x2121 (71.5x83.5) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1”) thick Cardinal insulated glass comprised of 3.9mm
(5/32”) tempered / 9.5mm (3/8”) Endur Spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_1210 Casement Picture IG.pdf Quality Assurance Contract Expiration Date 09/16/2025 Installation Instructions FL17694_R8_II_27845.05-1002 - 1210 Casement Pict Alternate Install Instr.pdf FL17694_R8_II_27845.06-107-16-R0 -Product Eval 1209-1210 Fixed Casement Windows.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.10 |
1309 Premium Impact Direct Set Mullion |
CW-PG55-MA 3632x2121 (143x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 7/16" Cardinal "LG" laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-005.17, .20,.21,.51 Impact Direct Set 1310 2-wide.pdf Quality Assurance Contract Expiration Date 06/15/2025 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf FL17694_R8_II_WS Nail Fin Install.pdf FL17694_R8_II_WS Through Jamb Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.11 |
1309 Premium Impact Direct Set, Single Glazed |
CW-PG65-FW 1143x3048 (45x120) Nail Fin Install
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 17/32" Cardinal "LG" laminated glass comprised of (1/4") annealed / .090" SGP / (1/4") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-005.24,26,27 Impact Direct Set 1309 9_16_26.pdf Quality Assurance Contract Expiration Date 09/16/2026 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.12 |
1309 Premium Impact Direct Set, Single Glazed |
CW-PG65-FW 1143x3048 (45x120) Through Jamb Installation |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 23/32" Cardinal "LG" laminated glass comprised of (5/16") annealed / .090" SGP / (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-005.24,26,27 Impact Direct Set 1309 9_16_26.pdf Quality Assurance Contract Expiration Date 09/16/2026 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.13 |
1310 Premium Impact Direct Set Mullion |
CW-PG55-MA 3632x2121 (143x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1" insulated glass comprised 6.3mm (1/4") tempered / 8mm (5/16") Super Spacer / 3.9mm (5/32") / .090" SGP / 3.9 (5/32") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-005.17, .20,.21,.51 Impact Direct Set 1310 2-wide.pdf Quality Assurance Contract Expiration Date 06/15/2025 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf FL17694_R8_II_WS Nail Fin Install.pdf FL17694_R8_II_WS Through Jamb Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.14 |
1310 Premium Impact Direct Set, Dual Glazed |
CW-PG65-FW 1143x3048 (45x120) Fin Installation |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 1-1/4" insulated glass comprised of 6mm (1/4") tempered / 9.5mm (3/8") Super Spacer / 8mm (5/16") / .090" SGP / 8mm (5/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-005.28,30,31 Impact Direct Set 1309 9_13_26.pdf Quality Assurance Contract Expiration Date 09/13/2026 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.15 |
1310 Premium Impact Direct Set, Dual Glazed |
CW-PG65-FW 1143x3048 (45x120) Clip Install |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 1-1/8" insulated glass comprised of 6mm (1/4") tempered / 9.5mm (3/8") Endur Spacer / 6mm (1/4") / .090" SGP / 6mm (1/4") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_1310 Premium Impact Direct Set, Dual Glazed (Report ESP019206P-1690.1).pdf Quality Assurance Contract Expiration Date 03/13/2025 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.16 |
1310 Premium Impact Direct Set, Dual Glazed |
CW-PG65-FW 1143x3048 (45x120) Through Jamb Install |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 1-1/8" insulated glass comprised of 6mm (1/4") tempered / 9.5mm (3/8") Endur Spacer / 6mm (1/4") / .090" SGP / 6mm (1/4") heat strengthened glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_449-H-005.28,30,31 Impact Direct Set 1309 9_13_26.pdf Quality Assurance Contract Expiration Date 09/13/2026 Installation Instructions FL17694_R8_II_85-7849-14-Alt-2023.pdf FL17694_R8_II_EvalReport-1310-DS-2023.pdf FL17694_R8_II_WS Direct Set Clip Install.pdf FL17694_R8_II_WS Nail Fin Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.17 |
Premium Coastal Double Hung Tilt Transom (1110) SG |
CW-PG55-1207x1054 (48x42)-FW |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: utilized single nominal (11/32”) thick Cardinal “LG” laminated glass comprised of
(1/8”) annealed / .090” PVB / (1/8”) annealed glass. The glass was set
from the interior against silicone back bedding. In
addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_Premium Coastal Double Hung Tilt Transom (1110) SG.pdf Quality Assurance Contract Expiration Date 07/28/2025 Installation Instructions FL17694_R8_II_1110-1111 Ind DH Transom Installation Instruction -- Nail Fin-Thru Jamb-Installation Clips 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17694.18 |
Premium Coastal Double Hung Tilt Transom (1111) IG |
CW-PG55-1207x1054 (48x42)-FW |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Utilized nominal 19mm (3/4") thick
insulated glass comprised of 3.9mm (5/32”) tempered / 8.0mm (5/16”) Endur Spacer / 2.3mm (3/32”) / .090” PVB /
2.3mm (3/32”) annealed glass. The glass was set
from the interior against silicone back bedding. In
addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17694_R8_C_CAC_Premium Coastal Double Hung Tilt Transom (1111) IG.pdf Quality Assurance Contract Expiration Date 07/28/2025 Installation Instructions FL17694_R8_II_1110-1111 Ind DH Transom Installation Instruction -- Nail Fin-Thru Jamb-Installation Clips 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |