FL # FL20745-R5
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
darius@emfab.net
 
Authorized Signature Darius Moura
darius@emfab.net
 
Technical Representative Darius Moura
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
darius@emfab.net
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report David Eng
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/27/2033
Validated By James R Wally, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL20745_R5_COI_26ga_EMax_16ga_Structural.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922017
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/05/2023
Date Validated 12/08/2023
Date Pending FBC Approval 12/12/2023
Date Approved 02/13/2024
 
Summary of Products
FL # Model, Number or Name Description
20745.1 01: 26ga EMax on 16ga Purlins 26ga (min) EMax Ag Rib panel on 16ga (min) steel purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-110
 Other: Refer to evaluation report.
Installation Instructions
 FL20745_R5_II_26ga_EMax_16ga_Structural.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20745_R5_AE_26ga_EMax_16ga_Structural.pdf
 Created by Independent Third Party: Yes
20745.2 02: 26ga PBRMax on 16ga Purlins 26ga (min) PBRMax panel on 16ga (min) steel purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105
 Other: Refer to evaluation report
Installation Instructions
 FL20745_R5_II_26ga_PBRMax_16ga_Structural.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
Evaluation Reports
 FL20745_R5_AE_26ga_PBRMax_16ga_Structural.pdf
 Created by Independent Third Party: Yes
 