Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL17163-R7
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer Marvin
Address/Phone/Email Hwy 11 West
Warroad, MN 56763
(218) 386-1430   Ext 2143
cherylf@marvin.com
 
Authorized Signature Chelsie Horner
ChelsieH@marvin.com
 
Technical Representative Chelsie Horner
Address/Phone/Email 401 State Ave N
Warroad, MN 56763
(800) 346-5044   Ext 1734
chelsieh@marvin.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Mullions
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 4502010
AAMA/WDMA/CSA 101/I.S.2/A4402017
AAMA/WDMA/CSA 101/I.S.2/A4402011
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 10/13/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
17163.1 Essential 1/2" MRF 114" X 96" 2W1H Essential 1/2" MRF MULL 2W1H, 407-H-1133
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Max Size: 95.5" Span x 57.0" Trib Wd - Vertical; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in MRF 114X96 2W1H.pdf
Quality Assurance Contract Expiration Date
 02/06/2034
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.2 Essential 1/2" MRF 60" x 96" 2W2H Essential 1/2" MRF MULL 2W2H, 407-H-1133
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Max Size 59.5" Span x 48.0" Trib Wd - Horizontal; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in MRF 60x96 2W2H.pdf
Quality Assurance Contract Expiration Date
 02/06/2034
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.3 Essential 1/2" MRF 71.5" x 99.5" 1W2H Essential 1/2" MRF MULL 1W2H, 407-H-1133
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Max Size: 71.5" Span x 45.0" Trib Wd - Horizontal; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in MRF 72x100 1W2H.pdf
Quality Assurance Contract Expiration Date
 02/05/2034
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.4 Essential 1/2" MRF 96" x 96" 1W2H Essential 1/2" MRF MULL 1W2H, 407-H-1133
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Max Size: 95.5" Span x 48.0" Trib Wd - Horizontal; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_ES MRF MULL 1W2H CCL 1171.12.13.14.pdf
Quality Assurance Contract Expiration Date
 02/06/2034
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.5 Essential 1/2" MRF 96" x 96" 2W2H Essential 1/2" MRF MULL 2W2H, 407-H-1171
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Max Size: 95.5" Span x 48.0" Trib Wd Horizontal; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in MRF 96x96 2W2H.pdf
Quality Assurance Contract Expiration Date
 02/06/2034
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.6 Essential 1/2" Standard Mull, 114" x 96" 1W2H Essential 1/2" Standard Mull 1W2H, 407-H-1170
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Max Size: 95.5" Span x 57.0" Trib Wd; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in Standard Mull, 114 x 96 1W2H.pdf
Quality Assurance Contract Expiration Date
 10/02/2033
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.7 Essential 1/2" Standard Mull, 60" x 96" 2W2H Essential 1/2" Standard Mull 2W2H, 407-H-1170
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Max Size: 59.5" Span x 48.0" Trib Wd; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in Standard Mull, 60 x 96 2W2H.pdf
Quality Assurance Contract Expiration Date
 10/02/2033
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.8 Essential 1/2" Standard Mull, 72" x 100" 1W2H Essential 1/2" Standard Mull 1W2H, 407-H-1170
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Max Size: 71.5" Span x 45.0" Trib Wd; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in Standard Mull, 72 x 100 1W2H.pdf
Quality Assurance Contract Expiration Date
 10/02/2033
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.9 Essential 1/2" Standard Mull, 72" x 96" 2W2H Essential 1/2" Standard Mull 2W2H, 407-H-1170
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Max Size: 95.5" Span x 36.0" Trib Wd; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in Standard Mull, 72 x 96 2W2H.pdf
Quality Assurance Contract Expiration Date
 10/02/2033
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.10 Essential 1/2" Standard Mull, 96" x 100" 1W2H Essential 1/2" Standard Mull 1W2H, 407-H-1170
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Max Size: 95.5" Span x 50.0" Trib Wd; Approved for use as a door mull. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 in Standard Mull, 96 x 100 1W2H.pdf
Quality Assurance Contract Expiration Date
 04/01/2034
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
17163.11 Essential 1/2" Standard Mull, 96" x 96" 1W2H Essential 1/2" Standard Mull 1W2H, 407-H-1170
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: Max Size: 95.5" Span x 48.0" Trib Wd; Approved for use with all window types. When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC 9th Edition (2026).
Certification Agency Certificate
 FL17163_R7_C_CAC_Essential .5 Standard Mull, 96 x 96 1W2H.pdf
Quality Assurance Contract Expiration Date
 10/02/2033
Installation Instructions
 FL17163_R7_II_00090279_7.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex