| 16994.1 |
Gooseneck Vent |
Gooseneck vents with 4", 6", and 10" square ducts and height of 8-5/8" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-142.5 Other: See Evaluation Report for limits of use. |
Installation Instructions FL16994_R10_II_SEM14001.10c 2026 FBC Eval Gooseneck Vent final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R10_AE_SEM14001.10c 2026 FBC Eval Gooseneck Vent final.pdf Created by Independent Third Party: Yes |
|
|
| 16994.2 |
Gooseneck Vent Tile |
Gooseneck vents with 4", 6", and 10" square ducts and height of 9-9/16" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-172.5 Other: See Evaluation Report for limits of use. |
Installation Instructions FL16994_R10_II_SEM14001.10e 2026 FBC Eval Gooseneck Vent Tile final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R10_AE_SEM14001.10e 2026 FBC Eval Gooseneck Vent Tile final.pdf Created by Independent Third Party: Yes |
|
|
| 16994.3 |
Off Ridge Vent |
4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-18 Other: See evaluation report for limits of use. |
Installation Instructions FL16994_R10_II_SEM14001.10a 2026 FBC Eval Off-Ridge Vent final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R10_AE_SEM14001.10a 2026 FBC Eval Off-Ridge Vent final.pdf Created by Independent Third Party: Yes |
|
|
| 16994.4 |
Tile Off Ridge Vent |
4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-9 Other: See Evaluation Report for limits of use. |
Installation Instructions FL16994_R10_II_SEM14001.10b 2026 FBC Eval Tile Roof Vent final.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R10_AE_SEM14001.10b 2026 FBC Eval Tile Roof Vent final.pdf Created by Independent Third Party: Yes |
|
|
| 16994.5 |
Total JACK |
Steel vent with maximum 8-inch throat at base opening and an octagonal flange base with a diameter of 15-inches. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-262.5 Other: See Evaluation Report for limits of use. |
Installation Instructions FL16994_R10_II_SEM14001.10d 2026 FBC Eval Total Jack final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL16994_R10_AE_SEM14001.10d 2026 FBC Eval Total Jack final.pdf Created by Independent Third Party: Yes |