Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL16991-R9
Application Type Revision
Code Version 2026
Application Status Validated
 
Comments
Archived
 
Product Manufacturer C.H.I. Overhead Doors
Address/Phone/Email 1485 Sunrise Drive
Arthur, IL 61911
(217) 543-2135   Ext 4292
vanessa.wood@nucor.com
 
Authorized Signature Vanessa Wood
vanessa.wood@nucor.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Roll-Up Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report John E. Scates
Florida License PE-51737
Quality Assurance Entity Architectural Testing, Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Kurt Dietrich PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL16991_R9_COI_Cert_of_Ind_Scates_2026_CHI_sFL.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082017
ANSI/DASMA 1152017
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/16/2026
Date Validated 10/16/2026
 
Summary of Products
FL # Model, Number or Name Description
16991.1 FL-16991.01; 6181, 6201, 6221, 6266 08'-4" maximum wide by 24' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +34.7/-43.1
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z7-8-90007 for 8'-04" width and pressure +34.7/-43.1 (psf).
Installation Instructions
 FL16991_R9_II_z7-8-90007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.2 FL-16991.02; 6181, 6201, 6221, 6266 10'-4" maximum wide by 24' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30.0/-36.8
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z6-10-90007 for 10'-04" width and pressure +30.0/-36.8 (psf).
Installation Instructions
 FL16991_R9_II_z6-10-90007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.3 FL-16991.03; 6202, 6222, 6242 10'-4" maximum wide by 24' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +34.7/-43.1
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z7-10-91007 for 10'-04" width and pressure +34.7/-43.1 (psf).
Installation Instructions
 FL16991_R9_II_z7-10-91007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.4 FL-16991.04; 6181, 6201, 6221, 6266 12'-4" maximum wide by 24' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +23.7/-28.4
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z5-12-90007 for 12'-04" width and pressure +23.7/-28.4 (psf).
Installation Instructions
 FL16991_R9_II_z5-12-90007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.5 FL-16991.05; 6202, 6222, 6242 12'-4" maximum wide by 24' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30.0/-36.8
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z6-12-91007 for 12'-04" width and pressure +30.0/-36.8 (psf).
Installation Instructions
 FL16991_R9_II_z6-12-91007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.6 FL-16991.06; 6181, 6201, 6221, 6266 14'-4" maximum wide by 24' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +20.0/-24.3
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z4-14-90007 for 14'-04" width and pressure +20.0/-24.3 (psf).
Installation Instructions
 FL16991_R9_II_z4-14-90007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.7 FL-16991.07; 6202, 6222, 6242 14'-4" maximum wide by 24' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +23.7/-28.4
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing z5-14-91007 for 14'-04" width and pressure +23.7/-28.4 (psf).
Installation Instructions
 FL16991_R9_II_z5-14-91007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.8 FL-16991.08; 6202, 6222, 6242 16'-4" maximum wide by 24' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +20.0/-24.0
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing z3-16-91007 for 16'-04" width and pressure +20.0/-24.0 (psf).
Installation Instructions
 FL16991_R9_II_z3-16-91007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.9 FL-16991.09; 6181, 6201, 6221, 6266 16'-4" maximum wide by 30' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +56/-56
 Other: Roll up doors provided for potential "code-plus" applications. Large Missile impact (9 pound missile) and cycling tests conducted in accordance with ANSI/DASMA 115. Static tests conducted in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z11i-16-94008 for widths and pressures +/-56 (psf) at 8'-4" through +/-56 (psf) at 16'-4".
Installation Instructions
 FL16991_R9_II_z11i-16-94008_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.10 FL-16991.10; 6202, 6222, 6242 16'-4" maximum wide by 30' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +56/-56
 Other: Roll up doors provided for potential "code-plus" applications. Large Missile impact (9 pound missile) and cycling tests conducted in accordance with ANSI/DASMA 115. Static tests conducted in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z11i-16-95008 for widths and pressures +/-56 (psf) at 8'-4" through +/-56 (psf) at 16'-4".
Installation Instructions
 FL16991_R9_II_z11i-16-95008_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.11 FL-16991.11; 6181, 6201, 6221, 6266 16'-4" maximum wide by 30' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +136/-136
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z12-12-92007 for widths and pressures +/-136 (psf) at 8'-4" through +/-56 (psf) at 16'-4".
Installation Instructions
 FL16991_R9_II_z12-12-92007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.12 FL-16991.12; 6202, 6222, 6242 16'-4" maximum wide by 30' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +136/-136
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z12-12-93007 for widths and pressures +/-136 (psf) at 8'-4" through +/-56 (psf) at 16'-4".
Installation Instructions
 FL16991_R9_II_z12-12-93007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.13 FL-16991.13; 6181, 6201, 6221, 6266 20'-4" maximum wide by 30' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +74/-74
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z12-16-92007 for widths and pressures +/-74 (psf) at 12'-4" through +/-38 (psf) at 20'-4".
Installation Instructions
 FL16991_R9_II_z12-16-92007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.14 FL-16991.14; 6202, 6222, 6242 20'-4" maximum wide by 30' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +74/-74
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z12-16-93007 for widths and pressures +/-74 (psf) at 12'-4" through +/-38 (psf) at 20'-4".
Installation Instructions
 FL16991_R9_II_z12-16-93007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.15 FL-16991.15; 6181, 6201, 6221, 6266 30'-4" maximum wide wide by 30' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z5-26-92008 for widths and pressures +/-30 (psf) at 22'-4" through +/-20 (psf) at 30'-4".
Installation Instructions
 FL16991_R9_II_z5-26-92008_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.16 FL-16991.16; 6202, 6222, 6242 30'-4" maximum wide wide by 30' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z5-26-93008 for widths and pressures +/-30 (psf) at 22'-4" through +/-20 (psf) at 30'-4".
Installation Instructions
 FL16991_R9_II_z5-26-93008_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.17 FL-16991.17; 6181, 6201, 6221, 6266 30'-4" maximum wide by 30' maximum high roll up door with steel slats.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-70
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z12-26-92007 for widths and pressures +/-70 (psf) at 22'-4" through +/-48 (psf) at 30'-4".
Installation Instructions
 FL16991_R9_II_z12-26-92007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
16991.18 FL-16991.18; 6202, 6222, 6242 30'-4" maximum wide by 30' maximum high roll up door with steel face slats, steel backer slats, and filled with urethane insulation.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-70
 Other: Roll up doors provided for windload applications. Tested in accordance with ASTM E330 and ANSI/DASMA 108. See drawing Z12-26-93007 for widths and pressures +/-70 (psf) at 22'-4" through +/-48 (psf) at 30'-4".
Installation Instructions
 FL16991_R9_II_z12-26-93007_sFLTX.pdf
 Verified By: John E. Scates, P.E. FL-51737
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16991_R9_AE_FL16991 Eval_Rept_s.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex