| 2681.1 |
Bertha Colonial Shutter with clips or storm bars- (Non-HVHZ) Drawing# 26-102 |
Extruded aluminum blades assembled together and retained by jambs/headers to provide hurricane protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile.Max.width is 72" and max.height is 54" for double panels(square)with clips and +65,-65 psf A.S.D.design load,and max.width is 144" and max. height is 54" for quadruple panels(square)with clips.See sheets 13 and 14 for additional schedules.Max width is 36.5” with Max. height of 67” for +60,-81 psf double (square) panels with storm bars or max. width is 61” with 73” max. height for +51,-70 psf quadruple (square)panels with storm bars. |
Installation Instructions FL2681_R8_II_Drawing 26-102.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL2681_R8_AE_PE Report 26-0630.02A Drawing 26-102.pdf Created by Independent Third Party: Yes |
|
|
| 2681.2 |
Bertha Colonial Shutter with Storm Bars-(HVHZ)- Drawing# 26-101 |
Extruded aluminum blades assembled together and retained by jambs/headers to provide hurricane protection |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile. Max.width is 36.5" and max. height is 67" for +60, -81 p.s.f. A.S.D. design load for double panel shutter and max. width is 63" and max. height is 73" for +51, -70 p.s.f. A.S.D design load for quadruple panels shutter. |
Installation Instructions FL2681_R8_II_Drawing 26-101.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL2681_R8_AE_PE Report Drawing 26-101.pdf Created by Independent Third Party: Yes |