| 26840.1 |
A - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 37.38" x 81.75" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.12-R2.pdf FL26840_R14_C_CAC_NI013981.31-R2.pdf Quality Assurance Contract Expiration Date 03/31/2030 Installation Instructions FL26840_R14_II_ARCH FG OPQ IS NI HVHZ FBC 37x82 SS 2018-05-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_PER5667 SS 2018-07-31.pdf Created by Independent Third Party: Yes |
|
|
| 26840.2 |
B - Architectural Fiberglass |
Inswing Door 1 Panel X Opaque 43.51" x 97.63" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-70 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.13-R2.pdf Quality Assurance Contract Expiration Date 03/31/2030 Installation Instructions FL26840_R14_II_ARCH FG OPQ IS NI HVHZ FBC 43x97 SS 2018-05-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_PER5668 SS 2018-07-31.pdf Created by Independent Third Party: Yes |
|
|
| 26840.3 |
C - Architectural Fiberglass |
Outswing Door 1 Panel X Opaque 37.31" x 81.75" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.14-R2.pdf FL26840_R14_C_CAC_NI013981.35-R2.pdf Quality Assurance Contract Expiration Date 03/31/2030 Installation Instructions FL26840_R14_II_ARCH FG OPQ OS NI HVHZ FBC 37x82 SS 2018-05-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_PER5669 SS 2018-07-31.pdf Created by Independent Third Party: Yes |
|
|
| 26840.4 |
D - Architectural Fiberglass |
Outswing Door 1 Panel X Opaque 43.25" x 96.38" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-70 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.15-R2.pdf Quality Assurance Contract Expiration Date 03/31/2030 Installation Instructions FL26840_R14_II_ARCH FG OPQ OS NI HVHZ FBC 43x97 SS 2018-05-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_PER5670 SS 2018-07-31.pdf Created by Independent Third Party: Yes |
|
|
| 26840.5 |
E - Architectural Fiberglass |
Inswing Door 1 Panel X Glazed 37.38" x 81.75" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.32-R2.pdf FL26840_R14_C_CAC_NI013981.37-R2.pdf Quality Assurance Contract Expiration Date 02/28/2030 Installation Instructions FL26840_R14_II_A-Tech FG IS Full Lite NI HVHZ FBC SS 2019-06-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_PER6277 SS 2019-06-17.pdf Created by Independent Third Party: Yes |
|
|
| 26840.6 |
F - Architectural Fiberglass |
Outswing Door 1 Panel X Glazed 37.38" x 81.75" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-55 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.33-R2.pdf FL26840_R14_C_CAC_NI013981.36-R2.pdf Quality Assurance Contract Expiration Date 02/28/2030 Installation Instructions FL26840_R14_II_A-Tech FG OS Full Lite NI HVHZ FBC SS 2019-06-17.pdf Verified By: Hermes Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_PER6283 SS 2019-06-17.pdf Created by Independent Third Party: Yes |
|
|
| 26840.7 |
G - Architectural Fiberglass |
Inswing Door 2 Panel XX Opaque 73.94" x 80.69" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI013981.52-R3.pdf Quality Assurance Contract Expiration Date 10/31/2030 Installation Instructions FL26840_R14_II_D015591 (26840.7) - Architectural Fiberglass Swinging Door Inswing 2 Panel 74x82 DP50 O-HVHZ-NI FBC_9-28-26 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_SCE 26-09016 - 26840.7 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 26840.8 |
H - Architectural Fiberglass |
Inswing Door 2 Panel XX Glazed 73.75" x 81.69" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI016380-R1.pdf Quality Assurance Contract Expiration Date 10/31/2030 Installation Instructions FL26840_R14_II_A-Tech FG Inswing Glazed 73.75x81.6875 50-50 FBC Installs_10-24-24 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_MS 24-10003 Calcs R1 Admin DSS.pdf Created by Independent Third Party: Yes |
|
|
| 26840.9 |
I - Architectural Fiberglass |
Outswing Door 2 Panel XX Glazed 74" x 80.5" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI016380.01-R2.pdf Quality Assurance Contract Expiration Date 10/31/2030 Installation Instructions FL26840_R14_II_D015786 (26840.9) - Architectural Fiberglass Swinging Door Outswing 2 Panel 74x80.5 DP50 G-HVHZ-NI FBC_9-28-26 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_SCE 26-09017 - 26840.9 Calcs DSS.pdf Created by Independent Third Party: Yes |
|
|
| 26840.10 |
J - Architectural Fiberglass |
Outswing Door 2 Panel XX Opaque 86" x 96.25" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI016380.02-R1.pdf Quality Assurance Contract Expiration Date 10/31/2030 Installation Instructions FL26840_R14_II_A-Tech FG Outswing Opaque 86x96.25 50-50 FBC Installs_10-24-24 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_MS 24-10005 Calcs R1 Admin DSS.pdf Created by Independent Third Party: Yes |
|
|
| 26840.11 |
K - Architectural Fiberglass |
Outswing Door 2 Panel XX Glazed 86" x 96.25" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Anchors within 3000 ft of the coast must comply with section 1711 of the current FBC. |
Certification Agency Certificate FL26840_R14_C_CAC_NI016380.03-R1.pdf Quality Assurance Contract Expiration Date 10/31/2030 Installation Instructions FL26840_R14_II_A-Tech FG Outswing Opaque 86x96.25 50-50 FBC Installs_10-24-24 DSS.pdf Verified By: Micah Swartz, P.E. 93573 Created by Independent Third Party: Yes Evaluation Reports FL26840_R14_AE_MS 24-10006 Calcs R1 Admin DSS.pdf Created by Independent Third Party: Yes |