Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL12942-R7
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer The Airolite Company, LLC
Address/Phone/Email PO Box 410
525 Western Road
Schofield, WI 54476
(715) 355-2242
mike.steele@airolite.com
 
Authorized Signature Michael Steele
mike.steele@airolite.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Wall Louver
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Chander P. Nangia
Florida License PE-21938
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 02/04/2026
Validated By Locke Bowden P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL12942_R7_COI_FPA 12942 K605MD PE Eval Report 2021-8-18.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/AMCA 5402008
TAS-2011994
TAS-2021994
TAS-2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL12942_R7_Equiv_FPA 12942 K605MD PE Eval Report 2021-8-18.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 03/23/2021
Date Validated 08/26/2021
Date Pending FBC Approval 10/25/2021
Date Approved 12/15/2021
Date Revised 10/20/2023
 
Summary of Products
FL # Model, Number or Name Description
12942.1 K605MD Hurricane Louver 5" Deep Horizontal Blade Louver, Extruded Aluminum, Hurricane Impact & Structural Resistant
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +110/-110
 Other: Rated for Enhanced Protection Missile Impact Level E (80 fps). Not rated for AMCA 550 or TAS 100(A), but may be installed in a location where the room behind the louver is designed to drain water penetrating into the room and the room will house water resistant/proof equipment, components, and/or supplies. Has not been evaluated for installation into cracked concrete substrate.
Installation Instructions
 FL12942_R7_II_FPA 12942 K605MD PE Eval Report 2021-8-18.pdf
 Verified By: Chander P. Nangia 21938
 Created by Independent Third Party: Yes
Evaluation Reports
 FL12942_R7_AE_FPA 12942 K605MD PE Eval Report 2021-8-18.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex