| 12938.1 |
Impervia Awning |
27-1/2" x 29-1/2" Vent Awning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTM E1300 standard. |
Certification Agency Certificate FL12938_R8_C_CAC_411-H-1449.08 Hallmark CCL.pdf Quality Assurance Contract Expiration Date 03/19/2023 Installation Instructions FL12938_R8_II_Drawing 1676.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL12938_R8_AE_Drawing 1676.pdf Created by Independent Third Party: Yes |
|
|
| 12938.2 |
Impervia Awning |
59-1/2" x 59-1/2" Large Vent Awning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Configurations of glass shall conform to current ASTM E1300 standard. |
Certification Agency Certificate FL12938_R8_C_CAC_411-H-1449.04 Hallmark CCL.pdf Quality Assurance Contract Expiration Date 02/12/2023 Installation Instructions FL12938_R8_II_Drawing 1676.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL12938_R8_AE_Drawing 1676.pdf Created by Independent Third Party: Yes |
|
|
| 12938.3 |
Impervia Awning |
53-1/2" x 29-1/2" Vent Awning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTM E1300 standard. |
Certification Agency Certificate FL12938_R8_C_CAC_411-H-1449.05 Hallmark CCL.pdf Quality Assurance Contract Expiration Date 02/13/2023 Installation Instructions FL12938_R8_II_Drawing 1676.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL12938_R8_AE_Drawing 1676.pdf Created by Independent Third Party: Yes |
|
|
| 12938.4 |
Impervia Awning |
41-1/2" x 59-1/2" Large Vent Awning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTM E1300 standard. |
Certification Agency Certificate FL12938_R8_C_CAC_411-H-1449.07 Hallmark CCL.pdf Quality Assurance Contract Expiration Date 02/13/2023 Installation Instructions FL12938_R8_II_Drawing 1676.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL12938_R8_AE_Drawing 1676.pdf Created by Independent Third Party: Yes |
|
|
| 12938.5 |
Impervia Awning |
41-1/2" x 41-1/2" Large Vent Awning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configurations of glass shall conform to current ASTM E1300 standard. |
Certification Agency Certificate FL12938_R8_C_CAC_411-H-1449.06 Hallmark CCL.pdf Quality Assurance Contract Expiration Date 02/13/2023 Installation Instructions FL12938_R8_II_Drawing 1676.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL12938_R8_AE_Drawing 1676.pdf Created by Independent Third Party: Yes |
|
|
| 12938.6 |
Impervia Awning |
59-1/2" x 41-1/2" Large Vent Awning |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Configurations of glass shall conform to current ASTM E1300 standard. |
Certification Agency Certificate FL12938_R8_C_CAC_411-H-1449.03 Hallmark CCL.pdf Quality Assurance Contract Expiration Date 02/12/2023 Installation Instructions FL12938_R8_II_Drawing 1676.pdf Verified By: Warren W. Schaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL12938_R8_AE_Drawing 1676.pdf Created by Independent Third Party: Yes |