| 38157.1 |
6120 All-Wood DH (48"x84") Mulled to 6122 All-Wood DH Picture (72"x84") |
Non-impact 6120 Wood DH Operator (48"x84") mulled to 6122 Wood DH Picture (72"x84"). Qualifies XO; OX and XOX configuration. LC-PG30 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glazing of DH Operator comprised of two lites of 1/8" annealed glass; Glazing of DH Picture comprised of two lites of 3/16" annealed glass. Glazing complies with ASTM E1300 requirements. |
Certification Agency Certificate FL38157_R2_C_CAC_6120-6122 449-H-118.07_.08_.09.pdf Quality Assurance Contract Expiration Date 04/06/2031 Installation Instructions FL38157_R2_II_45-30975 6120 6122 MULL rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 38157.2 |
6121 All-Wood DH Transom 72"x36" |
Non-impact 6121 All-Wood DH Transom 72"x36" (PG30) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glazing of DH Transom comprised of two lites of 1/8" annealed glass. Glazing complies with ASTM E1300 requirements. |
Certification Agency Certificate FL38157_R2_C_CAC_6121 449-H-118.15_.16.pdf Quality Assurance Contract Expiration Date 04/06/2031 Installation Instructions FL38157_R2_II_45-30962 6122 PICT 6121 TRAN STACK rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 38157.3 |
6122 All-Wood DH Picture 72"x84" |
Non-impact 6122 Wood DH Picture (72"x84"). PG30 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glazing of DH Picture comprised of two lites of 3/16" annealed glass. Glazing complies with ASTM E1300 requirements. |
Certification Agency Certificate FL38157_R2_C_CAC_6122 449-H-118.10_.11.pdf Quality Assurance Contract Expiration Date 04/06/2031 Installation Instructions FL38157_R2_II_45-30962 6122 PICT 6121 TRAN STACK rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 38157.4 |
6122 All-Wood DH Picture 72"x84" with 6121 All-Wood DH Transom 72"x36" Stacked Above |
Non-Impact 6122 All-Wood DH Picture 72"x84" with 6121 All-Wood DH Transom 72"x36" Stacked Above (PG30) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: Glazing of DH Transom comprised of two lites of 1/8" annealed glass; Glazing of DH Picture comprised of two lites of 3/16" annealed glass. Glazing complies with ASTM E1300 requirements. |
Certification Agency Certificate FL38157_R2_C_CAC_6122-6121 449-H-118.12_.13_.14.pdf Quality Assurance Contract Expiration Date 04/06/2031 Installation Instructions FL38157_R2_II_45-30962 6122 PICT 6121 TRAN STACK rev 1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 38157.5 |
8306 Direct Set Mulled 50"x120" |
Non-impact 8306 Direct Set (Mulled); Maximum Individual Frame Size of 50"x120" (R-PG60) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: Tested glazing consisted of two lites of 1/4" annealed glass. Units with individual frame sizes equal to or less than 29.5 sq. ft. produced with two lites of 1/4" annealed glass will comply with ASTM E1300. Any units with an individual frame size exceeding 46.5 sq. ft. require two lites of 1/4" tempered glass to meet ASTM E1300 requirements. |
Certification Agency Certificate FL38157_R2_C_CAC_8306 Direct Set 449-H-005.52 _.53.pdf Quality Assurance Contract Expiration Date 05/05/2030 Installation Instructions FL38157_R2_II_45-02505 Direct Sets 8306-8307-8312 rev 1.PDF Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 38157.6 |
8312 Flush Frame Direct Set 145"x74" |
Non-impact Flush Frame Direct Set; Maximum Individual Frame Size of 145"x74" CW-PG50. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Tested glazing consisted of two lites of 1/4" annealed glass. Units with individual frame sizes equal to or less than 46.5 sq. ft. produced with two lites of 1/4" annealed glass will comply with ASTM E1300. Any units with an individual frame size exceeding 46.5 sq. ft. require two lites of 1/4" tempered glass to meet E1300 requirements. |
Certification Agency Certificate FL38157_R2_C_CAC_8312 Flush Frame Direct Set 449-H-086.03.pdf Quality Assurance Contract Expiration Date 10/25/2027 Installation Instructions FL38157_R2_II_45-02505 Direct Sets 8306-8307-8312 rev 1.PDF Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |