| 17017.1 |
1209 Premium Impact Casement with Premium Impact Picture mulled alongside, Single Glazed, Vertical Mullion |
CW-PG65-MA 1975x1969 (78x78) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: The Pictures utilized (7/16") Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The Casements utilized (7/16") Cardinal laminated glass comprised of (3/16") annealed / .090" SGP / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.58, 62, 63, 64, 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-15_ Nail Fin.pdf FL17017_R9_II_85-7815-16_ Thru Jamb.pdf FL17017_R9_II_85-7815-17_ (Inatallation Clip).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.2 |
1209 Premium Impact Casement, Single Glazed |
CW-PG55-C 1054x2121 (42x84) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-70 Other: 3/8" annealed glass. The glass was set from the interior against silicone back bedding. In addition a back bed of silicone was used in the glazing pocket. Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.48 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.3 |
1209 Premium Impact Casement, Single Glazed |
CW-PG55-C 1054x2121 (42x84) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 7/16" Cardinal "LG" laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.32,36 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.4 |
1209 Premium Impact Casement, Single Glazed |
CW-PG65-C 902x1969 (36x78) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-85 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" SGP / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.56, 92,93 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-15_ Nail Fin.pdf FL17017_R9_II_85-7815-16_ Thru Jamb.pdf FL17017_R9_II_85-7815-17_ (Installation Clip).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.5 |
1209 Twin Premium Impact Casement , Single Glazed, Vertical Mullion |
LC-PG55-MA 2121x2121 (84x84) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 7/16" Cardinal "LG" laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.39,40,46,47 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-15_ Nail Fin.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.6 |
1209 Twin Premium Impact Casement with Premium Impact Picture Stacked Above, Single Glazed - Mulled Combination Assembly |
CW-PG55-MA 1810x3191 (71x126) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.65,66,68,69,70,71 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-21_.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.7 |
1209 Twin Premium Impact Casement with Premium Impact Picture Stacked Above, Single Glazed - Mullion |
CW-PG55-MA 2121x3188 (84x126) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 7/16" Cardinal laminated glass comprised of (3/16") annealed / .090" PVB / (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.50,51,53,54,55 1209 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-16_ Thru Jamb.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.8 |
1210 Casement Mulled to 1210 Casement Picture |
CW-PG55-MA 2731x2121 (107.5x83.5) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Casement: (1”) thick Cardinal insulated glass comprised of 3.9mm
(5/32”) annealed / 9.5mm (3/8”) Stainless Steel Spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) annealed. Picture: (1”) thick
Cardinal insulated glass comprised of 6.3mm (1/4”) annealed / 7.9mm (5/16”) Stainless Steel spacer / 4.7mm (3/16”) /
.090” PVB / 4.7mm (3/16”) annealed. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.83,84,85,86 1210 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-15_ Nail Fin.pdf FL17017_R9_II_85-7815-17_ (Installation Clip).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.9 |
1210 Premium Casement Impact |
DP +55/-70 psf, Large Missile Impact
DP +55/-70 psf, Missile D, Wind Zone 4 |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Casement: (1”) thick Cardinal insulated glass comprised of 3.9mm (5/32”) annealed / 9.5mm (3/8”) Stainless Steel Spacer / 4.7mm (3/16”) / .090” PVB / 4.7mm (3/16”) annealed. In addition, a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.88,95 1210 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7438-37 Single 1209-1210-8211 Install Clips.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.10 |
1210 Premium Impact Casement, Dual Glazed |
CW-PG55-C 1054x2121 (42x84) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1" insulated glass comprised 3.1mm (1/8") annealed / 13mm (1/2") Super Spacer / 3.1mm (1/8") / .090" PVB / 3.1 (1/8") annealed glass. The glass was set from the interior against silicone back bedding. In addition a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.32,36 1209_1210 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.11 |
1210 Premium Impact Casement, Dual Glazed |
CW-PG55-C 1054x2121 (42x84) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1" insulated glass comprised of 3.9mm (5/32") annealed / 9.5mm (3/8") Super Spacer / 4.7mm (3/16") / .090" SGP / 4.7mm (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.72,74,75 1210 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.12 |
1210 Premium Impact Casement, Dual Glazed |
CW-PG55-C 1054x2121 (42x84) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1" insulated glass comprised 3.1mm (1/8") annealed / 13mm (1/2") Super Spacer / 3.1mm (1/8") / .090" PVB / 3.1 (1/8") annealed glass. The glass was set from the interior against silicone back bedding. In addition a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.33,37 1210 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.13 |
1210 Premium Impact Pushout Casement, Dual Glazed |
R-PG55-C 905x1969 (36x78) |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 1" insulated glass comprised of 3.9mm (5/32") annealed / 9.5mm (3/8") Endur Spacer / 4.7mm (3/16") / .090" SGP / 4.7MM (3/16") annealed glass. The glass was set from the interior against silicone back bedding. In addition, a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.76,78,79 1210 Premium Impact Pushout Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 17017.14 |
1210 Twin Premium Impact Casement, Dual Glazed, Vertical Mullion |
LC-PG55-MA 2121x2121 (84x84) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: 3/4" insulated glass comprised 3.9mm (5/32") annealed / 6mm (1/4") Super Spacer / 3.1mm (1/8") / .090" PVB / 3.1 (1/8") annealed glass. The glass was set from the interior against silicone back bedding. In addition a back bed of silicone was used in the glazing pocket. (Missile D, Wind Zone 4) Glass Meets ASTM E1300 |
Certification Agency Certificate FL17017_R9_C_CAC_449-H-013.39,40,46,47 1209_1210 Premium Impact Casement.pdf Quality Assurance Contract Expiration Date 11/06/2029 Installation Instructions FL17017_R9_II_1209-1210-8211 Nail Fin (85-7438-36).pdf FL17017_R9_II_27845.01-107-16-R0 1209-1210 Casements Alternate Install.pdf FL17017_R9_II_85-7815-21_.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |