| 17022.1 |
01: 26ga VMax on Plywood |
26ga (min) VMax 5V panel with 24" coverage on 15/32" (min) plywood or 3/4" (min) thick wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-228 Other: Refer to evaluation report. |
Installation Instructions FL17022_R11_II_26ga_VMAX_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL17022_R11_AE_26ga_VMAX_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 17022.2 |
02: 032 Aluminum VMax on Plywood |
Nominally 0.032" aluminum (or thicker) VMax 5V panel with 21" coverage on 15/32" (min) plywood or 3/4" (min) thick wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: Refer to evaluation report. |
Installation Instructions FL17022_R11_II_032_VMAX_21in_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL17022_R11_AE_032_VMAX_21in_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 17022.3 |
03: 26ga VMax on Plywood |
26ga (min) VMax 5V panel with 24" coverage on 15/32" (min) plywood or 3/4" (min) thick wood plank. Option for fasteners in the flats and in the ribs. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-114.25 Other: Refer to evaluation report. |
Installation Instructions FL17022_R11_II_26ga_VMAX_plywood_flats.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL17022_R11_AE_26ga_VMAX_plywood_flats.pdf Created by Independent Third Party: Yes |
|
|
| 17022.4 |
04: 26ga CorMax on Plywood |
26ga (min) CorMax corrugated panel with 29.5" coverage on 15/32" (min) plywood or 3/4" (min) thick wood plank. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: Refer to evaluation report. |
Installation Instructions FL17022_R11_II_26ga_CorMax_Plywood_HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL17022_R11_AE_26ga_CorMax_Plywood_HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 17022.5 |
05: 26ga CorMax on Battens |
26ga (min) CorMax corrugated panel with 29.5" coverage on 2x4 (min) battens. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161 Other: Refer to evaluation report. |
Installation Instructions FL17022_R11_II_26ga_CorMax_Battens.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL17022_R11_AE_26ga_CorMax_Battens.pdf Created by Independent Third Party: Yes |