| 10765.1 |
Ultra Series French Inswing Door ADA sill w/thermal break |
74.875" x 98.59375", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel; Glass complies with the current ASTM E1300 standard; Full Lite |
Certification Agency Certificate FL10765_R11_C_CAC_25099 CCL.pdf Quality Assurance Contract Expiration Date 03/09/2036 Installation Instructions FL10765_R11_II_15085 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10765.2 |
Ultra Series French Inswing Door ADA sill w/thermal break |
74.875" x 98.59375", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: 5-pt lock active panel and 2-pt handle activated shoot bolt lock system passive panel; Glass complies with the current ASTM E1300 standard (3.9mm TE - 8.0mm SS - 3.9mm .090” SGP 3.9mm), Insulated Glazed, Impact Performance, Missile D, Wind Zone 3; Full Lite |
Certification Agency Certificate FL10765_R11_C_CAC_25099 CCL.pdf Quality Assurance Contract Expiration Date 03/09/2036 Installation Instructions FL10765_R11_II_15086 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10765.3 |
Ultra Series French Outswing Door |
74 7/8" x 98 19/32", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: 5-pt lock active panel, 2-pt handle activated shoot bolt lock system passive panel; Glass complies w/the current ASTM E1300 std (5.7mm Ann .090" SGP 5.7mm Ann & 3.9mm Ann .090" SGP 3.9mm Ann), Sgl Glzd, Impact Performance, Missile D, Wind Zone 4; Doors are available w/& w/o raised panels in designs both w/glass & full raised panels (no glass) in accordance w/the following guidelines – maximum raised panel height 62”, maximum mid/cross rail length 28-1/8”; Alum clad frame |
Certification Agency Certificate FL10765_R11_C_CAC_CCL 11161.pdf Quality Assurance Contract Expiration Date 08/03/2026 Installation Instructions FL10765_R11_II_11161_65 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10765.4 |
Ultra Series French Outswing Door |
74 7/8" x 98 19/32", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: 5-pt lock active panel and 2-pt handle activated shoot bolt lock system passive panel; Glass complies with the current ASTM E1300 standard (3.9mm T - 8.0mm SS - 3.9mm Ann .090” SGP 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; Doors are available w/& w/o raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height 62”, maximum mid/cross rail length 28-1/8”; Alum clad frame |
Certification Agency Certificate FL10765_R11_C_CAC_CCL 11165.pdf Quality Assurance Contract Expiration Date 08/03/2026 Installation Instructions FL10765_R11_II_11161_65 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10765.5 |
Ultra Series French Outswing Door w/ADA sill |
74-7/8" x 98-7/32", Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel; Glass complies with the current ASTM E1300 standard; Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame |
Certification Agency Certificate FL10765_R11_C_CAC_25098 Recert of 15083-15084 Extension.pdf Quality Assurance Contract Expiration Date 05/07/2027 Installation Instructions FL10765_R11_II_15083 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10765.6 |
Ultra Series French Outswing Door w/ADA sill |
74-7/8" x 98-7/32", Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +65/-65 Other: 5-pt lock active panel and 2-pt handle activated shootbolt lock system passive panel; Glass complies with the current ASTM E1300 standard (3.9mm T - 8.0mm SS - 3.9mm Ann .090” SGP 3.9mm Ann), Insulated Glazed, Impact Performance, Missile D, Wind Zone 4; Doors are available w/& w/o raised panels in designs both w/glass & full raised panels (no glass), in accordance w/the following guidelines – maximum raised panel height 62”, maximum mid/cross rail length 28-1/8”; Alum clad frame |
Certification Agency Certificate FL10765_R11_C_CAC_15084 Extension CCL.pdf FL10765_R11_C_CAC_25098 Recert of 15083-15084 Extension.pdf Quality Assurance Contract Expiration Date 05/07/2027 Installation Instructions FL10765_R11_II_15084 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10765.7 |
Ultra Series French Outswing Door/Fixed Door Mulled Assembly |
151 1/8" x 98 19/32", Reinforced Combination Mull, Non-impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: 5-point lock on active panel and 2-point handle activated shoot bolt lock system on passive panel; Glass complies with the current ASTM E1300 standard; Doors are available with & without raised panels in designs both with glass & full raised panels (no glass), in accordance with the following guidelines – maximum raised panel height is 62”, maximum mid/cross rail length is 28-1/8”; Alum clad frame
|
Certification Agency Certificate FL10765_R11_C_CAC_CCL 11160.pdf Quality Assurance Contract Expiration Date 08/03/2026 Installation Instructions FL10765_R11_II_11160 string.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |