| 11734.1 |
416/418 |
Extra Heavy-Duty Sectional Steel Commercial Door, 16ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +18/-18 Other: Drawing 410153, 30'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410153 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.2 |
416/418 |
Extra Heavy-Duty Sectional Steel Commercial Door, 16ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +22/-22 Other: Drawing 410154, 26'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410154 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.3 |
416/418 |
Extra Heavy-Duty Sectional Steel Commercial Door, 16ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +26/-26 Other: Drawing 410155, 24'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410155 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.4 |
416/418 |
Extra Heavy-Duty Sectional Steel Commercial Door, 16ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +31/-31 Other: Drawing 410156, 22'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410156 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.5 |
416/418 |
Extra Heavy-Duty Sectional Steel Commercial Door, 16ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +37/-37 Other: Drawing 410157, 18'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410157 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.6 |
416/418 |
Extra Heavy-Duty Sectional Steel Commercial Door, 16ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +50/-50 Other: Drawing 410216, 14'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410216 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.7 |
420/422 |
Heavy-Duty Sectional Steel Commercial Door, 20ga-galvanized, (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +18/-18 Other: Drawing 410158, 26'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410158 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.8 |
420/422 |
Heavy-Duty Sectional Steel Commercial Door, 20ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +22/-22 Other: Drawing 410159, 24'2" Max wide, 30'1" Height.The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410159 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.9 |
420/422 |
Heavy-Duty Sectional Steel Commercial Door, 20ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +26/-26 Other: Drawing 410160, 22'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410160 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.10 |
420/422 |
Heavy-Duty Sectional Steel Commercial Door, 20ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +31/-31 Other: Drawing 410161, 20'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410161 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.11 |
420/422 |
Heavy-Duty Sectional Steel Commercial Door, 20ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +37/-37 Other: Drawing 410162, 18'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410162 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.12 |
420/422 |
Heavy-Duty Sectional Steel Commercial Door, 20ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +50/-50 Other: Drawing 410217, 14'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410217 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.13 |
424/426 |
Heavy-Duty Sectional Steel Commercial Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +18/-18 Other: Drawing 410163, 26'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410163 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.14 |
424/426 |
Heavy-Duty Sectional Steel Commercial Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +22/-22 Other: Drawing 410164, 24'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410164 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.15 |
424/426 |
Heavy-Duty Commercial Sectional Steel Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +26/-26 Other: Drawing 410165, 22'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410165 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.16 |
424/426 |
Heavy-Duty Sectional Steel Commercial Door, 24ga-galvanized, (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +31/-31 Other: Drawing 410166, 20'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410166 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.17 |
424/426 |
Heavy-Duty Sectional Steel Commercial Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +37/-37 Other: Drawing 410167, 18'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410167 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.18 |
424/426 |
Heavy-Duty Sectional Steel Commercial Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Drawing 410218, 14'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410218 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.19 |
430/432 |
Medium-Duty Sectional Steel Commercial Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +18/-18 Other: Drawing 410168, 20'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410168 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |
|
|
| 11734.20 |
430/432 |
Medium-Duty Sectional Steel Commercial Door, 24ga-galvanized (Non-Insulated/Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +22/-22 Other: Drawing 410169, 20'2" Max wide, 30'1" Height. The optional glazing available DOES meet the wind load requirements of the building code but DOES NOT meet the impact resistant requirements for windborne debris regions. This product without glazing DOES comply with the impact resistant requirements for windborne debris areas. |
Installation Instructions FL11734_R10_II_408717 signed.pdf FL11734_R10_II_410169 signed.pdf Verified By: Gordon Thomas 46718 Created by Independent Third Party: Yes Evaluation Reports FL11734_R10_AE_OHD2025-001 Evaluation Report signed.pdf Created by Independent Third Party: Yes |