| 11762.1 |
5 V Crimp 26 Ga. |
5 V Crimp 26 Ga over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-165.5 Other: -108.5 psf @ 12" o.c. -156.5 psf @ 6" o.c. in panel rib |
Installation Instructions FL11762_R4_II_FL11762.1 R4 26 Ga. 5V-Crimp Roof Panel_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.1 R4 26 Ga. 5V-Crimp Roof Panel_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.2 |
Mechanical Lock |
1 1/2" Mechanical Lock 0.032" Aluminum 20" wide over 19/32" SEALED plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-72.5PSF Other: -72.5 psf @ 3'-0" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.2 R4 1.5 Mechanical Lock 0.032_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.2 R4 1.5 Mechanical Lock 0.032_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.3 |
Mechanical Lock |
1 1/2" Mechanical Lock 24 Ga. 16" wide over Plywood
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.3 R4 1.5 Mechanical Lock 24 Ga. Roof Panel_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.3 R4 1.5 Mechanical Lock 24 Ga. Roof Panel_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.4 |
Mechanical Lock |
2" Mechanical Lock 24 ga. 18 7/8" wide over 22 Ga. Metal Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -54.3 psf @ 36” O.C. Clip Spacing. -153.5 psf @ 6” O.C. Clip Spacing. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.4 R4 2 Mechanical Lock 24 Ga._sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.4 R4 2 Mechanical Lock 24 Ga._sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.5 |
Nail Strip |
1" Nail Strip 24 Ga. 16" wide over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5PSF Other: -59.75 psf @ 16" o.c. fastener spacing in slot. -101.0 psf @ 6 3/4" o.c. fastener spacing in slot. -153.5 psf @ 6 3/4" o.c. fastener in slot and 12" o.c. fasteners in Pan (See Details). Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.5 R4 1 Nailstrip 24 Ga._sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.5 R4 1 Nailstrip 24 Ga._sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.6 |
Nail Strip |
1 1/2" Nail Strip 24 Ga. 15 1/2" wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -78.5 psf @ 11" o.c. fastener in slot. -116.0 psf @ 6 1/2" o.c. fastener in slot and 12" o.c. fasteners in pan (See Details). For use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.6 R4 1.5 Nailstrip 24 Ga_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.6 R4 1.5 Nailstrip 24 Ga_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.7 |
Snap Lock |
1 1/2" Snap Lock 24 Ga. 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.7 R4 1.5 Snap Lock 24 Ga. Roof Panel_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.7 R4 1.5 Snap Lock 24 Ga. Roof Panel_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.8 |
Snap Lock |
1 3/4" Snap Lock 24 ga. 16" over 15/32" plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-79.25PSF Other: -79.25 psf @ 12" o.c. clip spacing. -74.25 psf @ 24" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL11762_R4_II_FL11762.8 R4 1.75 Snap Lock 24 Ga. Roof Panel_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.8 R4 1.75 Snap Lock 24 Ga. Roof Panel_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.9 |
US 100 NS |
1" Nailstrip Roof Panel, 0.032" Aluminum 16" Wide Roof Panel. Performed, Snap Together standing seam panel with integrated nail strip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-60psf Other: |
Installation Instructions FL11762_R4_II_FL11762.9 R4 1 Nailstrip 0.032 Aluminum_sealed_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.9 R4 1 Nailstrip 0.032 Aluminum_sealed_sealed.pdf Created by Independent Third Party: Yes |
|
|
| 11762.10 |
US 150 |
1.5" Mechanical Lock 24 Ga. 16" Wide Steel Roof Panel over 15/32" Plywood. Performed Standing Seam Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-112.5 Other: |
Installation Instructions FL11762_R4_II_FL11762.10 R4 1.5 Mechanical Lock 24 Ga._sealed_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL11762_R4_AE_FL11762.10 R4 1.5 Mechanical Lock 24 Ga._sealed_sealed.pdf Created by Independent Third Party: Yes |