Product Approval Menu > Application Detail
 
FL # FL11762-R4
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments Quality Assurance was called into question on 6.13.22. M.C.
Archived
 
Product Manufacturer Modern Metal Systems Incorporated
Address/Phone/Email 4530 126th Ave North
Clearwater, FL 33762
(727) 573-2255
angie.modernmetals@gmail.com
 
Authorized Signature Gary Wilson
angie.modernmetals@gmail.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/20/2027
Validated By Brian Jaks, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11762_R4_COI_Letter of Certification-Modern Metals_sealed.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1001995
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/08/2020
Date Validated 10/13/2020
Date Pending FBC Approval 10/22/2020
Date Approved 12/16/2020
 
Summary of Products
FL # Model, Number or Name Description
11762.1 5 V Crimp 26 Ga. 5 V Crimp 26 Ga over 15/32" Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-165.5
 Other: -108.5 psf @ 12" o.c. -156.5 psf @ 6" o.c. in panel rib
Installation Instructions
 FL11762_R4_II_FL11762.1 R4 26 Ga. 5V-Crimp Roof Panel_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.1 R4 26 Ga. 5V-Crimp Roof Panel_sealed.pdf
 Created by Independent Third Party: Yes
11762.2 Mechanical Lock 1 1/2" Mechanical Lock 0.032" Aluminum 20" wide over 19/32" SEALED plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-72.5PSF
 Other: -72.5 psf @ 3'-0" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.2 R4 1.5 Mechanical Lock 0.032_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.2 R4 1.5 Mechanical Lock 0.032_sealed.pdf
 Created by Independent Third Party: Yes
11762.3 Mechanical Lock 1 1/2" Mechanical Lock 24 Ga. 16" wide over Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123.5PSF
 Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.3 R4 1.5 Mechanical Lock 24 Ga. Roof Panel_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.3 R4 1.5 Mechanical Lock 24 Ga. Roof Panel_sealed.pdf
 Created by Independent Third Party: Yes
11762.4 Mechanical Lock 2" Mechanical Lock 24 ga. 18 7/8" wide over 22 Ga. Metal Deck
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5psf
 Other: -54.3 psf @ 36” O.C. Clip Spacing. -153.5 psf @ 6” O.C. Clip Spacing. Install per manufacturer's details. For use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.4 R4 2 Mechanical Lock 24 Ga._sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.4 R4 2 Mechanical Lock 24 Ga._sealed.pdf
 Created by Independent Third Party: Yes
11762.5 Nail Strip 1" Nail Strip 24 Ga. 16" wide over 15/32" plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5PSF
 Other: -59.75 psf @ 16" o.c. fastener spacing in slot. -101.0 psf @ 6 3/4" o.c. fastener spacing in slot. -153.5 psf @ 6 3/4" o.c. fastener in slot and 12" o.c. fasteners in Pan (See Details). Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.5 R4 1 Nailstrip 24 Ga._sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.5 R4 1 Nailstrip 24 Ga._sealed.pdf
 Created by Independent Third Party: Yes
11762.6 Nail Strip 1 1/2" Nail Strip 24 Ga. 15 1/2" wide over Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0PSF
 Other: -78.5 psf @ 11" o.c. fastener in slot. -116.0 psf @ 6 1/2" o.c. fastener in slot and 12" o.c. fasteners in pan (See Details). For use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.6 R4 1.5 Nailstrip 24 Ga_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.6 R4 1.5 Nailstrip 24 Ga_sealed.pdf
 Created by Independent Third Party: Yes
11762.7 Snap Lock 1 1/2" Snap Lock 24 Ga. 16" Wide over Plywood
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116.0PSF
 Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.7 R4 1.5 Snap Lock 24 Ga. Roof Panel_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.7 R4 1.5 Snap Lock 24 Ga. Roof Panel_sealed.pdf
 Created by Independent Third Party: Yes
11762.8 Snap Lock 1 3/4" Snap Lock 24 ga. 16" over 15/32" plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-79.25PSF
 Other: -79.25 psf @ 12" o.c. clip spacing. -74.25 psf @ 24" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL11762_R4_II_FL11762.8 R4 1.75 Snap Lock 24 Ga. Roof Panel_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.8 R4 1.75 Snap Lock 24 Ga. Roof Panel_sealed.pdf
 Created by Independent Third Party: Yes
11762.9 US 100 NS 1" Nailstrip Roof Panel, 0.032" Aluminum 16" Wide Roof Panel. Performed, Snap Together standing seam panel with integrated nail strip
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-60psf
 Other:  
Installation Instructions
 FL11762_R4_II_FL11762.9 R4 1 Nailstrip 0.032 Aluminum_sealed_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.9 R4 1 Nailstrip 0.032 Aluminum_sealed_sealed.pdf
 Created by Independent Third Party: Yes
11762.10 US 150 1.5" Mechanical Lock 24 Ga. 16" Wide Steel Roof Panel over 15/32" Plywood. Performed Standing Seam Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-112.5
 Other:  
Installation Instructions
 FL11762_R4_II_FL11762.10 R4 1.5 Mechanical Lock 24 Ga._sealed_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11762_R4_AE_FL11762.10 R4 1.5 Mechanical Lock 24 Ga._sealed_sealed.pdf
 Created by Independent Third Party: Yes
 