| 13631.1 |
ESCA FS 27"x71" |
Essential Casement 407-H-1034 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 27" x 71" inches. Configurations of glass conform to ASTM E1300. |
Certification Agency Certificate FL13631_R9_C_CAC_ESCA CCL 1034.13.14.pdf Quality Assurance Contract Expiration Date 07/30/2028 Installation Instructions FL13631_R9_II_00115053_0.1 - ELEVATION.pdf FL13631_R9_II_00115054_0.0 - METHOD.pdf FL13631_R9_II_66686.pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066687).pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066688).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL13631_R9_AE_EvalReport-ESCA-AWN-SWP FL13630,13631,13632.pdf Created by Independent Third Party: Yes |
|
|
| 13631.2 |
ESCA FS 27.5"x83.5" |
Essential Casement 407-H-1034.19-.20 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 27.5"x 83.5" inches. Configurations of glass conform to ASTM E1300. |
Certification Agency Certificate FL13631_R9_C_CAC_Marvin4071034 CCL.pdf Quality Assurance Contract Expiration Date 04/01/2034 Installation Instructions FL13631_R9_II_00066687_8.0 (1).pdf FL13631_R9_II_00066688.pdf FL13631_R9_II_00115053_0.1 - ELEVATION.pdf FL13631_R9_II_00115054_0.0 - METHOD.pdf FL13631_R9_II_66686.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL13631_R9_AE_EvalReport-ESCA-ESAWN-ESCAP.pdf Created by Independent Third Party: Yes |
|
|
| 13631.3 |
ESCA FS 30.3"x83.5" |
Essential Casement 407-H-1034.17-.18 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 30.3"x 83.5" inches. Configurations of glass conform to ASTM E1300. |
Certification Agency Certificate FL13631_R9_C_CAC_Marvin4071034 CCL.pdf Quality Assurance Contract Expiration Date 04/01/2034 Installation Instructions FL13631_R9_II_00066687_8.0 (1).pdf FL13631_R9_II_00066688.pdf FL13631_R9_II_00115053_0.1 - ELEVATION.pdf FL13631_R9_II_00115054_0.0 - METHOD.pdf FL13631_R9_II_66686.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL13631_R9_AE_EvalReport-ESCA-ESAWN-ESCAP.pdf Created by Independent Third Party: Yes |
|
|
| 13631.4 |
ESCA FS 35"x34" |
Essential Casement 407-H-1034 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 35" x 34" inches. Configurations of glass conform to ASTM E1300. |
Certification Agency Certificate FL13631_R9_C_CAC_ESCA CCL 1034.11.12.pdf Quality Assurance Contract Expiration Date 07/30/2028 Installation Instructions FL13631_R9_II_00115053_0.1 - ELEVATION.pdf FL13631_R9_II_00115054_0.0 - METHOD.pdf FL13631_R9_II_66686.pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066687).pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066688).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL13631_R9_AE_EvalReport-ESCA-AWN-SWP FL13630,13631,13632.pdf Created by Independent Third Party: Yes |
|
|
| 13631.5 |
ESCA FS 35"x54" |
Essential Casement 407-H-1034 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 35" x 54" inches. Configurations of glass conform to ASTM E1300. |
Certification Agency Certificate FL13631_R9_C_CAC_ESCA CCL 1034.09.10.pdf Quality Assurance Contract Expiration Date 07/30/2028 Installation Instructions FL13631_R9_II_00115053_0.1 - ELEVATION.pdf FL13631_R9_II_00115054_0.0 - METHOD.pdf FL13631_R9_II_66686.pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066687).pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066688).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL13631_R9_AE_EvalReport-ESCA-AWN-SWP FL13630,13631,13632.pdf Created by Independent Third Party: Yes |
|
|
| 13631.6 |
ESCA FS 35"x71" |
Essential Casement 407-H-1034 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Max Size: 35"x 71" inches. Configurations of glass conform to ASTM E1300. |
Certification Agency Certificate FL13631_R9_C_CAC_ESCA CCL 1034.07.08.pdf Quality Assurance Contract Expiration Date 07/30/2028 Installation Instructions FL13631_R9_II_00115053_0.1 - ELEVATION.pdf FL13631_R9_II_00115054_0.0 - METHOD.pdf FL13631_R9_II_66686.pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066687).pdf FL13631_R9_II_Installation 1034.07.08.09.10.11.12.13.14 (00066688).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL13631_R9_AE_EvalReport-ESCA-AWN-SWP FL13630,13631,13632.pdf Created by Independent Third Party: Yes |