Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL13560-R11
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Velux America, LLC
Address/Phone/Email P.O. Box 5001
Greenwood, SC 29648
(941) 400-6013
alan@kinneec.com
 
Authorized Signature Mike Rhoden
Mike.rhoden@velux.com
 
Technical Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Dr
Fort Mill, SC 29708
(864) 377-0691
mike.rhoden@velux.com
 
Quality Assurance Representative Mike Rhoden
Address/Phone/Email 104 Ben Casey Drive
Fort Mill, SC 29708
(803) 396-5736
mike.rhoden@velux.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402017
AAMA/WDMA/CSA 101/I.S.2/A4402011
ASTM E 18862013
ASTM E 19962014
TAS 201, 202, 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL13560_R11_Equiv_FL 13560 ASTM EQ.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/25/2025
Date Validated 07/28/2025
Date Pending FBC Approval
Date Approved 07/31/2025
 
Summary of Products
FL # Model, Number or Name Description
13560.1 [VCE or VCM or VCS] + [2004 or 2008 or 2099 94] Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 4646 and smaller (426-H-695.03)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +230/-55
 Other: SKG-PG55, max. size 1303mm x 1303mm. PG55 means minimum capacity is 55 psf. Glass meets ASTM E1300: 3mm clear tempered / 8.5mm st. stl. spacer / 5.7mm laminate using 2.5mm heat-strengthened panes and 0.030" PVB interlayer (with white coating for 2008 variant; with second Lo-E coating for 2099 94 variant). Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R11_C_CAC_FL13560 R8 VCE-VCM-VCS [4646 or smaller] 0004 or 0008.pdf
Quality Assurance Contract Expiration Date
 01/08/2030
Installation Instructions
 FL13560_R11_II_453525-2013-08_VCS.pdf
 FL13560_R11_II_VCM_VCE Installation Instructions w Underlayment.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13560.2 [VCE or VCM or VCS] + [2005 or 2099 93] Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 4646 and smaller (426-H-695.00)
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +230/-30
 Other: SKG-PG30, max. size 1303mm x 1303mm. PG30 means minimum capacity is 30 psf. Glass meets ASTM E1300: 3mm clear tempered / 10.5mm st. stl. spacer / 3mm clear tempered; (with second Lo-E coating for 2099 93 variant). Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R11_C_CAC_FL13560 R8 VCE-VCM-VCS [4646 or smaller] 0005 or 0099 93.pdf
Quality Assurance Contract Expiration Date
 12/26/2029
Installation Instructions
 FL13560_R11_II_453525-2013-08_VCS.pdf
 FL13560_R11_II_VCM_VCE Installation Instructions w Underlayment.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13560.3 [VCE or VCM or VCS] + 2006/2016 (HVHZ) Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 4646 and smaller (426-H-695.34/.38/.40/.48)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-60
 Other: Wind Zone 4, Missile D, Cycle Pressure +50/-50, max. size 1302mm x 1302mm. Tested pursuant to ASTM E 1886 and ASTM E 1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R11_C_CAC_FL13560 VCE-VCM-VCS 4646 or smaller - 06 or 16.pdf
Quality Assurance Contract Expiration Date
 08/07/2030
Installation Instructions
 FL13560_R11_II_453525-2013-08_VCS.pdf
 FL13560_R11_II_VCM_VCE Installation Instructions w Underlayment.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
13560.4 [VCE or VCM or VCS] + 2006/2016 (HVHZ) Aluminum-clad Rigid PVC, Curb Mount Venting Skylight, size 2246 and smaller (426-H-695.35/.39/.44/.45)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +80/-80
 Other: Wind Zone 4, Missile D, Cycle Pressure +70/-70, max. size 692mm x 1302mm. Tested pursuant to ASTM E 1886 and ASTM E 1996. Glass meets ASTM E1300: 3mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Certification Agency Certificate
 FL13560_R11_C_CAC_FL13560 VCE-VCM-VCS 2246 or smaller - 06 or 16.pdf
Quality Assurance Contract Expiration Date
 08/07/2030
Installation Instructions
 FL13560_R11_II_FL13560_VCM_VCE Installation Instructions w Underlayment.pdf
 FL13560_R11_II_FL13560_VCS Installation Instructions.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: