FL # FL6475-R7
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Kingspan Light & Air Fenestration, Inc.
Address/Phone/Email 28662 N. Ballard Drive
Lake Forest, IL 60045
(219) 313-7821
christopher.freeman@kingspan.com
 
Authorized Signature Christopher Freeman
christopher.freeman@kingspan.com
 
Technical Representative Michael Joseph
Address/Phone/Email 28862 Ballard Drive
Lake Forest, IL 60045
(979) 321-0347
michael.joseph@kingspan.com
 
Quality Assurance Representative Brian Langkan
Address/Phone/Email 28862 Ballard Drive
Lake Forest, IL 60045
(979) 321-0347
brian.langkan@kingspan.com
 
Category Sky Lights
Subcategory Skylight
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Hermes F.Norero
Florida License PE-73778
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL6475_R7_COI_COI Kingspan Light and Air Fenestration SS 2023-10-23.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E18862013
ASTM E19962017
ASTM E3302014
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 02/14/2024
Date Validated 02/27/2024
Date Pending FBC Approval 02/29/2024
Date Approved 04/16/2024
Date Revised 08/19/2026
 
Summary of Products
FL # Model, Number or Name Description
6475.1 Briteway Canopy System (HVHZ)(Impact) Briteway Canopy System (HVHZ)(Impact)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, purlin spacing, configurations, installation requirements and limits of use.
Installation Instructions
 FL6475_R7_II_KLA004 SS 2023-10-20.pdf
 Verified By: Hermes F. Norero, P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6475_R7_AE_PER8924 SS 2023-10-20.pdf
 Created by Independent Third Party: Yes
6475.2 Briteway Canopy System (HVHZ)(Non-Impact) Briteway Canopy System (HVHZ)(Non-Impact)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See Installation Instructions and Product Evaluation Report for allowable design pressures, purlin spacing, configurations, installation requirements and limits of use.
Installation Instructions
 FL6475_R7_II_KLA012 SS 2023-10-23.pdf
 Verified By: Hermes F. Norero, P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL6475_R7_AE_PER8976 SS 2023-10-23.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 