| 41654.1 |
01: 5V Crimp 26 Ga. |
5V 26 Ga. over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5psf Other: -108.5psf @ 12" O.C.,
-156.5psf @ 6" O.C. in panel rib
Install per manufacturers details. |
Installation Instructions FL41654_R2_II_26ga_5VCrimp_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_26ga_5VCrimp_Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41654.2 |
02: Mechanical Lock |
2" Mechanical Lock 24 Ga. 18 7/8 Wide over 22 Ga. Metal Deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -153.5 psf @ 6" O.C. clip spacing, -54.3 psf @ 36" O.C. clip spacing. Install per manufacturers details. |
Installation Instructions FL41654_R2_II_24ga_200Mechanical_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_200Mechanical_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 41654.3 |
03: Mechanical Lock |
1 1/2" Mechanical Lock 24 Ga. 16" Wide Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5psf Other: -59.75psf @ 24" O.C. clip spacing,
-123.5psf @ 6" O.C. clip spacing. Install per manufacturers details. |
Installation Instructions FL41654_R2_II_24ga_150Mechanical_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_150Mechanical_Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41654.4 |
04: Mechanical Lock |
1 1/2" Mechanical Lock 0.032" Aluminum 20" wide over 19/32" SEALED Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-72.5psf Other: -72.5 psf @ 36" O.C. clip spacing |
Installation Instructions FL41654_R2_II_032_Mechanical_Plywood_Sealed_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_032_Mechanical_Plywood_Sealed_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.5 |
05: Nail Strip |
1 1/2" Nail Strip 24 Ga. 15 1/2" wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -78.5 psf @ 11" O.C. fasteners in slot,
-116.0 psf @ 6 1/2" O.C fasteners in slot and 12" O.C. fasteners in pan. Install per manufacturers details. |
Installation Instructions FL41654_R2_II_24ga_150Nailstrip_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_150Nailstrip_Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41654.6 |
06: Nail Strip |
1" Nail Strip 24 Ga. 16" Wide over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -59.75 psf @ 16" O.C. fastener in slot. -153.5 psf @ 6 3/4" O.C. fastener in slot and 12" O.C. fasteners in pan
(See Details) |
Installation Instructions FL41654_R2_II_24ga_100Nailstrip_Plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_100Nailstrip_Plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.7 |
07: Snap Lock |
1 1/2" Snap Lock 24 Ga. 16" Wide over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -86.0 psf @ 24" O.C. clip spacing,
-108.5 psf @ 12" O.C. clip spacing,
-116.0 psf @ 6" O.C. clip spacing, Install per manufacturers details. |
Installation Instructions FL41654_R2_II_24ga_150Snaplock_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_150Snaplock_Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 41654.8 |
08: Snap Lock |
1 3/4" Snap Lock 24 Ga. 16" Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-79.25psf Other: -79.25 psf @ 12" O.C. clip spacing,
-74.25 psf @ 24" O.C. clip spacing,
Install per manufacturers details. |
Installation Instructions FL41654_R2_II_24ga_175_Snaplock_Plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_175_Snaplock_Plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.9 |
09: Nail Strip |
1" Nailstrip Roof Panel, 0.032" Aluminum 16" Wide Roof Panel. Performed, Snap Together standing seam panel with integrated nail strip |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-60.0psf Other: See evaluation report |
Installation Instructions FL41654_R2_II_032_100Nailstrip_Plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_032_100Nailstrip_Plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.10 |
10: Mechanical Lock |
1.5" Mechanical Lock 24 Ga. 16" Wide Steel Roof Panel over 15/32" Plywood. Performed Standing Seam Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.5psf Other: See evaluation report |
Installation Instructions FL41654_R2_II_24ga_150Mechanical_Plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_150Mechanical_Plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.11 |
11: 032 aluminum S1000 on plywood |
Nominally 0.032" aluminum or thicker MRS 1000 on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101 Other: See evaluation report. |
Installation Instructions FL41654_R2_II_032_S1000_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_032_S1000_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.12 |
12: 26ga 1" Nailstrip on plywood |
26ga (min) 1" Nailstrip panel on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See evaluation report. |
Installation Instructions FL41654_R2_II_26ga_nailstrip_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_26ga_nailstrip_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.13 |
13: 24ga 1" Nailstrip on OSB |
24ga (min) 1" Nailstrip panel on 7/16" (min) OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: See evaluation report. |
Installation Instructions FL41654_R2_II_24ga_nailstrip_OSB_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_24ga_nailstrip_OSB_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 41654.14 |
14: 032 aluminum MRS 1500 on OSB |
Nominally 0.032" aluminum or thicker MRS 1500 on 7/16" (min) OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: See evaluation report. |
Installation Instructions FL41654_R2_II_032Al_1500Mechanical_OSB_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL41654_R2_AE_032Al_1500Mechanical_OSB_nonHVHZ.pdf Created by Independent Third Party: Yes |