| 41685.1 |
IR501 - LMI & SMI |
IR501 Aluminum Storefront System |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +35.0/-35.0 Other: Storefront size, assembly, pressure and installation requirements are to be as specified in the attached drawing No. 102639D. Job required design wind pressure shall be calculated in accordance with the FBC Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This storefront system is rated as a WZ4 level "D" large missile impact and level "A" small missile impact product. All glass meets the requirements of the current ASTM E1300 standard. |
Installation Instructions FL41685_R1_II_KAW029 SS 2023-10-19.pdf Verified By: Hermes F. Norero 73778 Created by Independent Third Party: Yes Evaluation Reports FL41685_R1_AE_PER8916 SS 2023-11-02.pdf Created by Independent Third Party: Yes |