| 32606.1 |
G60I In-Swing Casement Window |
48" x 73" Casement window with nail fin or integral screw channel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-120 Other: These windows may not be installed at elevations over 30ft above grade unless protected by a code approved shutter. These windows are impact rated to wind zone 4, missile level D and glass meets the current ASTM E1300 standard. |
Certification Agency Certificate FL32606_R2_C_CAC_PP G601 XO IS Casement over Picture TAS AW PG80 -120 48x120.pdf Quality Assurance Contract Expiration Date 04/24/2025 Installation Instructions FL32606_R2_II_Drawing 1977.pdf FL32606_R2_II_G601 Glazing Detail.pdf Verified By: Warren W. Shaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32606_R2_AE_Drawing 1977.pdf Created by Independent Third Party: Yes |
|
|
| 32606.2 |
G60I In-Swing Casement Window |
48" x 120" Casement/picture window unit with nail fin or integral screw channel |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-120 Other: These windows may not be installed at elevations over 30ft above grade unless protected by a code approved shutter. These windows are impact rated to wind zone 4, missile level D and glass meets the current ASTM E1300 standard. |
Certification Agency Certificate FL32606_R2_C_CAC_PP G601 XO IS Casement over Picture TAS AW PG80 -120 48x120.pdf Quality Assurance Contract Expiration Date 04/24/2025 Installation Instructions FL32606_R2_II_Drawing 1977.pdf FL32606_R2_II_G601 Glazing Detail.pdf Verified By: Warren W. Shaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32606_R2_AE_Drawing 1977.pdf Created by Independent Third Party: Yes |
|
|
| 32606.3 |
G60I In-Swing Casement/Fixed Windows |
48" x 73" Casement window in receptor frame |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-120 Other: These windows may not be installed at elevations over 30ft above grade unless protected by a code approved shutter. These windows are impact rated to wind zone 4, missile level D and glass meets the current ASTM E1300 standard. |
Certification Agency Certificate FL32606_R2_C_CAC_PP G601 XO IS Casement over Picture Receptor Frame TAS AW PG80 -120 51x123.pdf Quality Assurance Contract Expiration Date 04/24/2025 Installation Instructions FL32606_R2_II_Drawing 1977.pdf FL32606_R2_II_G601 Glazing Detail.pdf Verified By: Warren W. Shaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32606_R2_AE_Drawing 1977.pdf Created by Independent Third Party: Yes |
|
|
| 32606.4 |
G60I In-Swing Casement/Fixed Windows |
48" x 120" Casemenet/picture window unit in receptor frame |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +80/-120 Other: These windows may not be installed at elevations over 30ft above grade unless protected by a code approved shutter. These windows are impact rated to wind zone 4, missile level D and glass meets the current ASTM E1300 standard. |
Certification Agency Certificate FL32606_R2_C_CAC_PP G601 XO IS Casement over Picture Receptor Frame TAS AW PG80 -120 51x123.pdf Quality Assurance Contract Expiration Date 04/24/2025 Installation Instructions FL32606_R2_II_Drawing 1977.pdf FL32606_R2_II_G601 Glazing Detail.pdf Verified By: Warren W. Shaefer, P.E. 44135 Created by Independent Third Party: Yes Evaluation Reports FL32606_R2_AE_Drawing 1977.pdf Created by Independent Third Party: Yes |