| 18386.1 |
Mechanical Lock |
1 1/2" Mechanical Lock over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. -123.5 psf @ 6" o.c. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL18386_R4_II_ML 150 24 Ga. over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL18386_R4_AE_ML 150 24 Ga. over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 18386.2 |
Nail Strip |
1 1/2" Nail Strip over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -78.5 psf @ 11" o.c. -116.0 psf @ 6 1/2" o.c. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL18386_R4_II_NS 150 24 Ga. over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL18386_R4_AE_NS 150 24 Ga. over Plywood HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 18386.3 |
Snap Lock |
1 1/2" Snap Lock over Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf @ 6" o.c. Install per manufacturer's details. For use in HVHZ Zones. |
Installation Instructions FL18386_R4_II_SL 150 24 Ga. over Plywood HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL18386_R4_AE_SL 150 24 Ga. over Plywood HVHZ.pdf Created by Independent Third Party: Yes |