| 18318.1 |
Arrowglass Base Sheet |
ASTM D 4601, Type II base sheet for mechanically fastened and adhered BUR applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL18318_R3_II_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL18318_R3_AE_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Created by Independent Third Party: Yes |
|
|
| 18318.2 |
MSA CVB "Channel Vent Base" |
ASTM D 4897 base sheet for mechanically fastened and adhered BUR applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL18318_R3_II_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL18318_R3_AE_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Created by Independent Third Party: Yes |
|
|
| 18318.3 |
MSA MG2 Base Sheet |
ASTM D 4601, Type II base sheet for mechanically fastened and adhered BUR applications. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL18318_R3_II_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL18318_R3_AE_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Created by Independent Third Party: Yes |
|
|
| 18318.4 |
MSA MSR |
ASTM D 3909 asphalt roll roofing surfaced with mineral granules for BUR applications |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL18318_R3_II_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL18318_R3_AE_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Created by Independent Third Party: Yes |
|
|
| 18318.5 |
MSA Ply 4 |
ASTM D 2178, Type IV ply sheet for hot mopped BUR applications |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL18318_R3_II_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL18318_R3_AE_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Created by Independent Third Party: Yes |
|
|
| 18318.6 |
MSA Ply 6 |
ASTM D 2178, Type IV ply sheet for hot mopped BUR applications |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. |
Installation Instructions FL18318_R3_II_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL18318_R3_AE_MSA15001.3 2023 FBC Eval MSA BUR final.pdf Created by Independent Third Party: Yes |