| 4891.1 |
CFR Panel |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.3 Other: Maximum uplift load of 183.3 psf @ support spacing of 24" o.c. with QuadLok seam and BA Series clip. |
Installation Instructions FL4891_R11_II_EvaluationReportC2727_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL4891_R11_AE_EvaluationReportC2727_4.pdf Created by Independent Third Party: Yes |
|
|
| 4891.2 |
Loc Seam 360 |
Min 24 ga., 16" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-157.5 Other: Uplift load of 157.5 psf at clip and S-5-U Mini clamp spacing of 24" o.c. |
Installation Instructions FL4891_R11_II_EvaluationReportC2727_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL4891_R11_AE_EvaluationReportC2727_5.pdf Created by Independent Third Party: Yes |
|
|
| 4891.3 |
R-Panel |
Min. 26 ga., 36" wide, through fastened panel over open supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limitations and load tables. |
Installation Instructions FL4891_R11_II_EvaluationReportC2727_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL4891_R11_AE_EvaluationReportC2727_6.pdf Created by Independent Third Party: Yes |