| 9820.1 |
a. Series 250C "SMI" |
Aluminum Casement Window "Small Missile Impact" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 9820.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. (Note - ASTM E1300-02 utilized for areas inside the HVHZ) |
Installation Instructions FL9820_R6_II_FL-9820.1 SUN-250C SMI.pdf Verified By: Gordon Thomas, P.E. 46718 Created by Independent Third Party: Yes Evaluation Reports FL9820_R6_AE_SM2016-019R2 Evaluation Report- FL9820-1.PDF Created by Independent Third Party: Yes |
|
|
| 9820.2 |
b. Series 250C "LMI" |
Aluminum Casement Window "Large Missile Impact" |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 9820.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. (Note - ASTM E1300-02 utilized for areas inside the HVHZ) |
Installation Instructions FL9820_R6_II_FL-9820.2 SUN-250C LMI.pdf Verified By: Gordon Thomas, P.E. 46718 Created by Independent Third Party: Yes Evaluation Reports FL9820_R6_AE_SM2016-020R3 Evaluation Report- FL9820-2.PDF Created by Independent Third Party: Yes |
|
|
| 9820.3 |
e. Series 300C |
Thermally Broken Aluminum Casement Window "Non-Impact" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See INST 9820.5 for any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL9820_R6_II_FL-9820.3 SUN-300C NI.pdf Verified By: Gordon Thomas, P.E. 46718 Created by Independent Third Party: Yes Evaluation Reports FL9820_R6_AE_SM2016-023R4 Evaluation Report- FL9820-3.PDF Created by Independent Third Party: Yes |
|
|
| 9820.4 |
f. Series 300C "SMI" |
Thermally Broken Aluminum Casement Window "Small Missile Impact" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 9820.6 for any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL9820_R6_II_FL-9820.4 SUN-300C SMI.pdf Verified By: Gordon Thomas, P.E. 46718 Created by Independent Third Party: Yes Evaluation Reports FL9820_R6_AE_SM2016-024R4 Evaluation Report- FL9820-4.PDF Created by Independent Third Party: Yes |
|
|
| 9820.5 |
g. Series 300C "LMI" |
Thermally Broken Aluminum Casement Window "Large Missile Impact" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See INST 9820.7 for any additional use limitations, installation instructions and product particulars. |
Installation Instructions FL9820_R6_II_FL-9820.5 SUN-300C LMI..pdf Verified By: Gordon Thomas, P.E. 46718 Created by Independent Third Party: Yes Evaluation Reports FL9820_R6_AE_SM2016-025R3 Evaluation Report- FL9820-5.PDF Created by Independent Third Party: Yes |