Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL9820-R6
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Sun Metals Systems, Inc.
Address/Phone/Email 5008 Tampa West Boulevard
Tampa, FL 33634
(813) 886-0240   Ext 231
jayhatton@sunmetalssystems.com
 
Authorized Signature Jay Hatton
jayhatton@sunmetalssystems.com
 
Technical Representative Eric C. VanHorn
Address/Phone/Email 5008 Tampa West Boulevard
Tampa, FL 33634
(813) 391-2649
evanhorn@vanhorneng.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Casement
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Gordon Thomas, PE
Florida License PE-46718
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2023
Validated By John E. Scates, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL9820_R6_COI_2020 FBC - Sun Metals Systems FL 9820.PDF
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA101/I.S.2/A4402011
ASTM E18862012
ASTM E19962017
ASTM E3302002
TAS 201, 202, 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL9820_R6_Equiv_2020 FBC - Sun Metals Systems Eq Product Stds FL 9820-2.PDF
FL9820_R6_Equiv_2020 FBC - Sun Metals Systems Eq Product Stds FL 9820-3.PDF
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/09/2020
Date Validated 10/13/2020
Date Pending FBC Approval 10/22/2020
Date Approved 12/15/2020
 
Summary of Products
FL # Model, Number or Name Description
9820.1 a. Series 250C "SMI" Aluminum Casement Window "Small Missile Impact"
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See INST 9820.1 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. (Note - ASTM E1300-02 utilized for areas inside the HVHZ)
Installation Instructions
 FL9820_R6_II_FL-9820.1 SUN-250C SMI.pdf
 Verified By: Gordon Thomas, P.E. 46718
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9820_R6_AE_SM2016-019R2 Evaluation Report- FL9820-1.PDF
 Created by Independent Third Party: Yes
9820.2 b. Series 250C "LMI" Aluminum Casement Window "Large Missile Impact"
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See INST 9820.2 for Design Pressure Ratings, any additional use limitations, installation instructions and product particulars. (Note - ASTM E1300-02 utilized for areas inside the HVHZ)
Installation Instructions
 FL9820_R6_II_FL-9820.2 SUN-250C LMI.pdf
 Verified By: Gordon Thomas, P.E. 46718
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9820_R6_AE_SM2016-020R3 Evaluation Report- FL9820-2.PDF
 Created by Independent Third Party: Yes
9820.3 e. Series 300C Thermally Broken Aluminum Casement Window "Non-Impact"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See INST 9820.5 for any additional use limitations, installation instructions and product particulars.
Installation Instructions
 FL9820_R6_II_FL-9820.3 SUN-300C NI.pdf
 Verified By: Gordon Thomas, P.E. 46718
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9820_R6_AE_SM2016-023R4 Evaluation Report- FL9820-3.PDF
 Created by Independent Third Party: Yes
9820.4 f. Series 300C "SMI" Thermally Broken Aluminum Casement Window "Small Missile Impact"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See INST 9820.6 for any additional use limitations, installation instructions and product particulars.
Installation Instructions
 FL9820_R6_II_FL-9820.4 SUN-300C SMI.pdf
 Verified By: Gordon Thomas, P.E. 46718
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9820_R6_AE_SM2016-024R4 Evaluation Report- FL9820-4.PDF
 Created by Independent Third Party: Yes
9820.5 g. Series 300C "LMI" Thermally Broken Aluminum Casement Window "Large Missile Impact"
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See INST 9820.7 for any additional use limitations, installation instructions and product particulars.
Installation Instructions
 FL9820_R6_II_FL-9820.5 SUN-300C LMI..pdf
 Verified By: Gordon Thomas, P.E. 46718
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9820_R6_AE_SM2016-025R3 Evaluation Report- FL9820-5.PDF
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex