| 38500.1 |
.1 HR-250 Captured Curtain Wall System; Large Missile Impact Laminated Glass |
Wall System made of Laminated Glass retained by aluminum profile frame, wet glazed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +90/-90 Other: Large Missile Impact Resistant. ASD Pressure rating: +/- 90 psf at 12'-6" span with mullion C and 5 ft spacing. See General Note 2, Sheet 1 of the installation drawing No. 21-057 for all pressure rating schedules. |
Installation Instructions FL38500_R2_II_OLD CASTLE BLDG ENV PED DRWG 21-057.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL38500_R2_AE_OLD CASTLE BLDG ENV PER DRWG 21-057.pdf Created by Independent Third Party: Yes |
|
|
| 38500.2 |
.2 HR-251 Captured Curtain Wall System Large & Small Missile Impact, Insulated Glass |
Wall System made of Insulated Glass retained by aluminum profile frame, wet glazed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +90/-90 Other: Large & Small Missile Impact Resistant. ASD pressure rating of +/- 90 psf for 12'-3" span w/ 5'-0" spacing of Mullion C. See General Note 2, Sheet 1 of installation drawing 21-058 for all pressure rating schedules. |
Installation Instructions FL38500_R2_II_OLD CASTLE BLDG ENV PED DRWG 21-058.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL38500_R2_AE_OLD CASTLE BLDG ENV PER DRWG 21-058.pdf Created by Independent Third Party: Yes |
|
|
| 38500.3 |
.3 HR-251 SSG Captured Curtain Wall System; Large & Small Missile Impact, Insulated Laminated Glass |
Wall System made of Insulated Glass retained by aluminum profile frame, wet glazed. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +90/-90 Other: Large & Small Missile Impact Resistant. ASD pressure rating of +/- 90 psf for 12'-0" span w/ 4'-0" spacing of Mullion C. See General Note 2, Sheet 1 of installation drawing 21-056 for all pressure rating schedules. |
Installation Instructions FL38500_R2_II_OLDCASTLE BLDG ENV PED DRWG 21-056.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL38500_R2_AE_OLDCASTLE BLDG ENV PER DRWG 21-056.pdf Created by Independent Third Party: Yes |
|
|
| 38500.4 |
.4 HR-250 DG Captured Dry Glazed Curtain Wall System with Large Missile Impact Laminated Glass |
Wall System made of Dry Glazed Laminated Glass retained by aluminum profile frame. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Large Missile Impact Resistant, see General Note 2, sheet 1 of installation drawing No. 21-068. ASD Pressure rating of +/- 70 psf for 12'-6" span w/ mullion C. See schedules on sheets 9 & 10 of installation drawing No. 21-068. See instructions on Sheet 1 of installation drawing No. 21-068. |
Installation Instructions FL38500_R2_II_Old Castle BldgEnv PED DRWG 21-068.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL38500_R2_AE_Old Castle BldgEnv PER drwg 21-068.pdf Created by Independent Third Party: Yes |
|
|
| 38500.5 |
.5 HR-251 DG Captured Dry Glazed Curtain Wall System Large Missile Impact Insulated Glass |
Wall system made of Dry Glazed Insulated Glass retained by aluminum profile frame. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: Large Missile Impact Resistant, see General Note No. 2, sheet 1 of installation drawing No. 21-069. ASD Pressure rating: +/- 70 psf for 12'-6" span w/ mullion C. See schedules on sheets 9 & 10 of installation drawing No. 21-069. See instructions on Sheet 1 of installation drawing No. 21-069. |
Installation Instructions FL38500_R2_II_Old Castle BldgEnv PED DRWG 21-069.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL38500_R2_AE_Old Castle BldgEnv PER drwg 21-069.pdf Created by Independent Third Party: Yes |