Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL38500-R2
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer OLDCASTLE BUILDING ENVELOPE
Address/Phone/Email 803 Airport Road
Terrell, TX 75150
(972) 551-6232
knolan@obe.com
 
Authorized Signature Kristin Nolan
knolan@obe.com
 
Technical Representative Bill Lang
Address/Phone/Email 803 Airport Rd
Terrell, TX 75150
(972) 551-6164
blang@obe.com
 
Quality Assurance Representative Marilee Murphy
Address/Phone/Email 8655 Elm Fair Blvd
Tampa, FL 33610
(813) 663-0949
mmurphy@obe.com
 
Category Panel Walls
Subcategory Curtain Walls
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Walter A. Tillit Jr., P.E.,
Florida License PE-44167
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2023
Validated By John W. Knezevich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL38500_R2_COI_Old Castle BldgEnv COI drwg 21-068.pdf
FL38500_R2_COI_Old Castle BldgEnv COI drwg 21-069.pdf
FL38500_R2_COI_OLDCASTLE BLDG ENV COI DRWG 21-056.pdf
FL38500_R2_COI_OLDCASTLE COI DRWG 21-057.pdf
FL38500_R2_COI_OLDCASTLE COI DRWG 21-058.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 5012015
ASTM E18862012
ASTM E19962012
ASTM E3302014
ASTM E3312009
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 09/30/2021
Date Validated 10/07/2021
Date Pending FBC Approval 10/11/2021
Date Approved 12/15/2021
Date Revised 08/14/2023
 
Summary of Products
FL # Model, Number or Name Description
38500.1 .1 HR-250 Captured Curtain Wall System; Large Missile Impact Laminated Glass Wall System made of Laminated Glass retained by aluminum profile frame, wet glazed.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +90/-90
 Other: Large Missile Impact Resistant. ASD Pressure rating: +/- 90 psf at 12'-6" span with mullion C and 5 ft spacing. See General Note 2, Sheet 1 of the installation drawing No. 21-057 for all pressure rating schedules.
Installation Instructions
 FL38500_R2_II_OLD CASTLE BLDG ENV PED DRWG 21-057.pdf
 Verified By: Walter A. Tillit Jr., P.E. PE 44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38500_R2_AE_OLD CASTLE BLDG ENV PER DRWG 21-057.pdf
 Created by Independent Third Party: Yes
38500.2 .2 HR-251 Captured Curtain Wall System Large & Small Missile Impact, Insulated Glass Wall System made of Insulated Glass retained by aluminum profile frame, wet glazed.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +90/-90
 Other: Large & Small Missile Impact Resistant. ASD pressure rating of +/- 90 psf for 12'-3" span w/ 5'-0" spacing of Mullion C. See General Note 2, Sheet 1 of installation drawing 21-058 for all pressure rating schedules.
Installation Instructions
 FL38500_R2_II_OLD CASTLE BLDG ENV PED DRWG 21-058.pdf
 Verified By: Walter A. Tillit Jr., P.E. PE 44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38500_R2_AE_OLD CASTLE BLDG ENV PER DRWG 21-058.pdf
 Created by Independent Third Party: Yes
38500.3 .3 HR-251 SSG Captured Curtain Wall System; Large & Small Missile Impact, Insulated Laminated Glass Wall System made of Insulated Glass retained by aluminum profile frame, wet glazed.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +90/-90
 Other: Large & Small Missile Impact Resistant. ASD pressure rating of +/- 90 psf for 12'-0" span w/ 4'-0" spacing of Mullion C. See General Note 2, Sheet 1 of installation drawing 21-056 for all pressure rating schedules.
Installation Instructions
 FL38500_R2_II_OLDCASTLE BLDG ENV PED DRWG 21-056.pdf
 Verified By: Walter A. Tillit Jr., P.E. PE 44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38500_R2_AE_OLDCASTLE BLDG ENV PER DRWG 21-056.pdf
 Created by Independent Third Party: Yes
38500.4 .4 HR-250 DG Captured Dry Glazed Curtain Wall System with Large Missile Impact Laminated Glass Wall System made of Dry Glazed Laminated Glass retained by aluminum profile frame.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: Large Missile Impact Resistant, see General Note 2, sheet 1 of installation drawing No. 21-068. ASD Pressure rating of +/- 70 psf for 12'-6" span w/ mullion C. See schedules on sheets 9 & 10 of installation drawing No. 21-068. See instructions on Sheet 1 of installation drawing No. 21-068.
Installation Instructions
 FL38500_R2_II_Old Castle BldgEnv PED DRWG 21-068.pdf
 Verified By: Walter A. Tillit Jr., P.E. PE 44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38500_R2_AE_Old Castle BldgEnv PER drwg 21-068.pdf
 Created by Independent Third Party: Yes
38500.5 .5 HR-251 DG Captured Dry Glazed Curtain Wall System Large Missile Impact Insulated Glass Wall system made of Dry Glazed Insulated Glass retained by aluminum profile frame.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: Large Missile Impact Resistant, see General Note No. 2, sheet 1 of installation drawing No. 21-069. ASD Pressure rating: +/- 70 psf for 12'-6" span w/ mullion C. See schedules on sheets 9 & 10 of installation drawing No. 21-069. See instructions on Sheet 1 of installation drawing No. 21-069.
Installation Instructions
 FL38500_R2_II_Old Castle BldgEnv PED DRWG 21-069.pdf
 Verified By: Walter A. Tillit Jr., P.E. PE 44167
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38500_R2_AE_Old Castle BldgEnv PER drwg 21-069.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: