Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL10188-R15
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Marvin
Address/Phone/Email Hwy 11 West
Warroad, MN 56763
(218) 386-1430   Ext 2143
cherylf@marvin.com
 
Authorized Signature Scott Lemke
f_scottl@marvin.com
 
Technical Representative Scott Lemke
Address/Phone/Email 1320 9th St NE
West Fargo, ND 58078
(701) 499-3600   Ext 3662
f_scottl@marvin.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402008
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402017
ASTM E 18862005
ASTM E 18862013
ASTM E 1996 2009
ASTM E 1996 2014
ASTM E 1996 2017
 
Equivalence of Product Standards
Certified By

Approved Certification Agency
FL10188_R15_Equiv_WDMA Techical Bulletin 2019-01 ASTM E1996.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/08/2025
Date Validated 12/16/2025
Date Pending FBC Approval
Date Approved 12/17/2025
 
Summary of Products
FL # Model, Number or Name Description
10188.1 ELCAP IZ3 3263 Elevate Casement Picture, Transom and Stationary - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-900
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: No
 Impact Resistant: No
 Design Pressure: +55/-65
 Other: Maximum size: 32" x 63". Wind zone 3 missile level D. All glass complies with ASTM E 1300.
Certification Agency Certificate
 FL10188_R15_C_CAC_ELCAP IZ3 CCL 900.46.47.50.pdf
Quality Assurance Contract Expiration Date
 04/08/2029
Installation Instructions
 FL10188_R15_II_Install 900.42 - .50 (00052395).pdf
 FL10188_R15_II_Install 900.42 - .50 (00137286).pdf
 FL10188_R15_II_Install 900.42 - .50 (00138642).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.2 ELCAP IZ3 5771 Elevate Casement Picture, Transom and Stationary - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-900
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 56" x 71". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_ELCAP IZ3 CCL 900.42.43.48.pdf
Quality Assurance Contract Expiration Date
 04/08/2029
Installation Instructions
 FL10188_R15_II_Install 900.42 - .50 (00052395).pdf
 FL10188_R15_II_Install 900.42 - .50 (00137286).pdf
 FL10188_R15_II_Install 900.42 - .50 (00138642).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.3 ELCAP IZ3 7355 Elevate Casement Picture, Transom and Stationary - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-900
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 72" x 55". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_ELCAP IZ3 CCL 900.44.45.49.pdf
Quality Assurance Contract Expiration Date
 04/08/2029
Installation Instructions
 FL10188_R15_II_Install 900.42 - .50 (00052395).pdf
 FL10188_R15_II_Install 900.42 - .50 (00137286).pdf
 FL10188_R15_II_Install 900.42 - .50 (00138642).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.4 ELDG CA RT IZ3 7229 Elevate Direct Glaze Casement Round Top - IZ3, 407-H-1125
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 72" x 29". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/9.5 mm airspace/ 6.9 mm PVB lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_Marvin4071125 CA 1830x751mmCCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2030
Installation Instructions
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.5 ELDG CA RT IZ3 8383 Elevate Direct Glaze Casement Round Top - IZ3, 407-H-1125
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 83" x 83". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (5.7mm T/9.5 mm airspace/ 10.1 mm SGP lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_Marvin4071125 CA 2111x2111mmCCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2030
Installation Instructions
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.6 ELDG DH RT IZ3 7229 Elevate Direct Glaze Double Hung Round Top - IZ3, 407-H-1125
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 72" x 29". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/9.5 mm airspace/ 6.9 mm PVB lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_Marvin4071125 DH 1830x751mmCCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2030
Installation Instructions
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.7 ELDG DH RT IZ3 8383 Elevate Direct Glaze Double Hung Round Top - IZ3, 407-H-1125
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 83" x 83". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (5.7mm T/9.5 mm airspace/ 10.1 mm SGP lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_Marvin4071125 DH 2111x2111mmCCL.pdf
Quality Assurance Contract Expiration Date
 06/26/2030
Installation Instructions
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf
 FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.8 ELDG IZ3 7330 Elevate Direct Glaze - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-876
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 72" x 29.5". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/13.0 mm airspace/ 6.9 mm PVB lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_CCL 876.89.90.91.pdf
Quality Assurance Contract Expiration Date
 12/12/2029
Installation Instructions
 FL10188_R15_II_Install 876.89 - .94 (00051692).pdf
 FL10188_R15_II_Install 876.89 - .94 (00058956).pdf
 FL10188_R15_II_Install 876.89 - .94 (00120778).pdf
 FL10188_R15_II_Install 879.89 - .94 (00120773).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.9 ELDG IZ3 9672 Elevate Direct Glaze - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-876
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 95" x 71.5". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (5.7mm T/9.8 mm airspace/ 10.1 mm PVB lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_CCL 876.92.93.94.pdf
Quality Assurance Contract Expiration Date
 12/12/2029
Installation Instructions
 FL10188_R15_II_Install 876.89 - .94 (00051692).pdf
 FL10188_R15_II_Install 876.89 - .94 (00058956).pdf
 FL10188_R15_II_Install 876.89 - .94 (00120778).pdf
 FL10188_R15_II_Install 879.89 - .94 (00120773).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
10188.10 ELDHP IZ3 4252 Elevate Double Hung Picture - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-793
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 41.5" x 53.75". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up 3.1mm /7.5 mm airspace/ 6.9 mm PVB lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_ELDHP IZ3 CCL 793.68.69.pdf
Quality Assurance Contract Expiration Date
 06/08/2028
Installation Instructions
 FL10188_R15_II_Install 793.67 - .73 (00052704).pdf
 FL10188_R15_II_Install 793.67 - .73 (00115659).pdf
 FL10188_R15_II_Install 793.67 - .73 (00115660).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL10188_R15_AE_EvalReport-ELDHP.pdf
 Created by Independent Third Party: Yes
10188.11 ELDHP IZ3 5476 Elevate Double Hung Picture - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-793
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 53.5" x 75.75". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_Marvin407793 DH 1359x1924mmCCL.pdf
Quality Assurance Contract Expiration Date
 06/08/2028
Installation Instructions
 FL10188_R15_II_Install 793.67 - .73 (00052704).pdf
 FL10188_R15_II_Install 793.67 - .73 (00115659).pdf
 FL10188_R15_II_Install 793.67 - .73 (00115660).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL10188_R15_AE_EvalReport-ELDHP.pdf
 Created by Independent Third Party: Yes
10188.12 ELDHP IZ3 6264 Elevate Double Hung Picture - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-793
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-65
 Other: Maximum size: 61.5" x 63.75". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami)
Certification Agency Certificate
 FL10188_R15_C_CAC_ELDHP IZ3 CCL 793.71.72.73.pdf
Quality Assurance Contract Expiration Date
 06/08/2028
Installation Instructions
 FL10188_R15_II_Install 793.67 - .73 (00052704).pdf
 FL10188_R15_II_Install 793.67 - .73 (00115659).pdf
 FL10188_R15_II_Install 793.67 - .73 (00115660).pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 FL10188_R15_AE_EvalReport-ELDHP.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex