| 10188.1 |
ELCAP IZ3 3263 |
Elevate Casement Picture, Transom and Stationary - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-900 |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: No Design Pressure: +55/-65 Other: Maximum size: 32" x 63". Wind zone 3 missile level D. All glass complies with ASTM E 1300. |
Certification Agency Certificate FL10188_R15_C_CAC_ELCAP IZ3 CCL 900.46.47.50.pdf Quality Assurance Contract Expiration Date 04/08/2029 Installation Instructions FL10188_R15_II_Install 900.42 - .50 (00052395).pdf FL10188_R15_II_Install 900.42 - .50 (00137286).pdf FL10188_R15_II_Install 900.42 - .50 (00138642).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.2 |
ELCAP IZ3 5771 |
Elevate Casement Picture, Transom and Stationary - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-900 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 56" x 71". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami) |
Certification Agency Certificate FL10188_R15_C_CAC_ELCAP IZ3 CCL 900.42.43.48.pdf Quality Assurance Contract Expiration Date 04/08/2029 Installation Instructions FL10188_R15_II_Install 900.42 - .50 (00052395).pdf FL10188_R15_II_Install 900.42 - .50 (00137286).pdf FL10188_R15_II_Install 900.42 - .50 (00138642).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.3 |
ELCAP IZ3 7355 |
Elevate Casement Picture, Transom and Stationary - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-900 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 72" x 55". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami) |
Certification Agency Certificate FL10188_R15_C_CAC_ELCAP IZ3 CCL 900.44.45.49.pdf Quality Assurance Contract Expiration Date 04/08/2029 Installation Instructions FL10188_R15_II_Install 900.42 - .50 (00052395).pdf FL10188_R15_II_Install 900.42 - .50 (00137286).pdf FL10188_R15_II_Install 900.42 - .50 (00138642).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.4 |
ELDG CA RT IZ3 7229 |
Elevate Direct Glaze Casement Round Top - IZ3, 407-H-1125 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 72" x 29". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/9.5 mm airspace/ 6.9 mm PVB lami) |
Certification Agency Certificate FL10188_R15_C_CAC_Marvin4071125 CA 1830x751mmCCL.pdf Quality Assurance Contract Expiration Date 06/26/2030 Installation Instructions FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.5 |
ELDG CA RT IZ3 8383 |
Elevate Direct Glaze Casement Round Top - IZ3, 407-H-1125 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 83" x 83". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (5.7mm T/9.5 mm airspace/ 10.1 mm SGP lami) |
Certification Agency Certificate FL10188_R15_C_CAC_Marvin4071125 CA 2111x2111mmCCL.pdf Quality Assurance Contract Expiration Date 06/26/2030 Installation Instructions FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.6 |
ELDG DH RT IZ3 7229 |
Elevate Direct Glaze Double Hung Round Top - IZ3, 407-H-1125 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 72" x 29". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/9.5 mm airspace/ 6.9 mm PVB lami) |
Certification Agency Certificate FL10188_R15_C_CAC_Marvin4071125 DH 1830x751mmCCL.pdf Quality Assurance Contract Expiration Date 06/26/2030 Installation Instructions FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.7 |
ELDG DH RT IZ3 8383 |
Elevate Direct Glaze Double Hung Round Top - IZ3, 407-H-1125 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 83" x 83". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (5.7mm T/9.5 mm airspace/ 10.1 mm SGP lami) |
Certification Agency Certificate FL10188_R15_C_CAC_Marvin4071125 DH 2111x2111mmCCL.pdf Quality Assurance Contract Expiration Date 06/26/2030 Installation Instructions FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089839).pdf FL10188_R15_II_Install 1125.00.01.02.03.10.11.12 (00089844).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.8 |
ELDG IZ3 7330 |
Elevate Direct Glaze - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-876 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 72" x 29.5". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/13.0 mm airspace/ 6.9 mm PVB lami) |
Certification Agency Certificate FL10188_R15_C_CAC_CCL 876.89.90.91.pdf Quality Assurance Contract Expiration Date 12/12/2029 Installation Instructions FL10188_R15_II_Install 876.89 - .94 (00051692).pdf FL10188_R15_II_Install 876.89 - .94 (00058956).pdf FL10188_R15_II_Install 876.89 - .94 (00120778).pdf FL10188_R15_II_Install 879.89 - .94 (00120773).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.9 |
ELDG IZ3 9672 |
Elevate Direct Glaze - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-876 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 95" x 71.5". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (5.7mm T/9.8 mm airspace/ 10.1 mm PVB lami) |
Certification Agency Certificate FL10188_R15_C_CAC_CCL 876.92.93.94.pdf Quality Assurance Contract Expiration Date 12/12/2029 Installation Instructions FL10188_R15_II_Install 876.89 - .94 (00051692).pdf FL10188_R15_II_Install 876.89 - .94 (00058956).pdf FL10188_R15_II_Install 876.89 - .94 (00120778).pdf FL10188_R15_II_Install 879.89 - .94 (00120773).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 10188.10 |
ELDHP IZ3 4252 |
Elevate Double Hung Picture - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-793 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 41.5" x 53.75". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up 3.1mm /7.5 mm airspace/ 6.9 mm PVB lami) |
Certification Agency Certificate FL10188_R15_C_CAC_ELDHP IZ3 CCL 793.68.69.pdf Quality Assurance Contract Expiration Date 06/08/2028 Installation Instructions FL10188_R15_II_Install 793.67 - .73 (00052704).pdf FL10188_R15_II_Install 793.67 - .73 (00115659).pdf FL10188_R15_II_Install 793.67 - .73 (00115660).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10188_R15_AE_EvalReport-ELDHP.pdf Created by Independent Third Party: Yes |
|
|
| 10188.11 |
ELDHP IZ3 5476 |
Elevate Double Hung Picture - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-793 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 53.5" x 75.75". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami) |
Certification Agency Certificate FL10188_R15_C_CAC_Marvin407793 DH 1359x1924mmCCL.pdf Quality Assurance Contract Expiration Date 06/08/2028 Installation Instructions FL10188_R15_II_Install 793.67 - .73 (00052704).pdf FL10188_R15_II_Install 793.67 - .73 (00115659).pdf FL10188_R15_II_Install 793.67 - .73 (00115660).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10188_R15_AE_EvalReport-ELDHP.pdf Created by Independent Third Party: Yes |
|
|
| 10188.12 |
ELDHP IZ3 6264 |
Elevate Double Hung Picture - IZ3, Fiberglass Clad Wood Fixed Window with Impact Glazing, 407-H-793 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-65 Other: Maximum size: 61.5" x 63.75". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/7.0 mm airspace/ 6.9 mm SGP lami) |
Certification Agency Certificate FL10188_R15_C_CAC_ELDHP IZ3 CCL 793.71.72.73.pdf Quality Assurance Contract Expiration Date 06/08/2028 Installation Instructions FL10188_R15_II_Install 793.67 - .73 (00052704).pdf FL10188_R15_II_Install 793.67 - .73 (00115659).pdf FL10188_R15_II_Install 793.67 - .73 (00115660).pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports FL10188_R15_AE_EvalReport-ELDHP.pdf Created by Independent Third Party: Yes |