Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL40551-R2
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Condado Window
Address/Phone/Email 903 RH Todd Avenue
San Juan, NON-US 00907
(787) 723-5469
justin@condadowindow.com
 
Authorized Signature Justin Vanbever
justin@condadowindow.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Casement
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Hermes F. Norero, P.E.
Florida License PE-73778
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2025
Validated By Zachary R. Priest, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL40551_R2_COI_COI - Condado Window SS 2024-05-02.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E18862019
ASTM E19962020
ASTM E2832019
ASTM E3302014
ASTM E3312000
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL40551_R2_Equiv_Condado ASTM E1996 Equivalency Statement.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 05/02/2024
Date Validated 05/02/2024
Date Pending FBC Approval 05/07/2024
Date Approved 06/18/2024
 
Summary of Products
FL # Model, Number or Name Description
40551.1 325 Series Casement Window (HVHZ) (Impact) 325 Series Casement Window (HVHZ) (Impact)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Evaluation Report for allowable design pressures, configurations, sizes, installations requirements and limits of use.
Installation Instructions
 FL40551_R2_II_CDW014 SS 2024-05-02.pdf
 Verified By: Hermes F. Norero 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL40551_R2_AE_PER9226 SS 2024-05-02.pdf
 Created by Independent Third Party: Yes
40551.2 325 Series Casement Window with Integral Shutter (HVHZ) (Impact) 325 Series Casement Window with Integral Shutter (HVHZ) (Impact)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Evaluation Report for allowable design pressures, configurations, sizes, installations requirements and limits of use.
Installation Instructions
 FL40551_R2_II_CDW003 SS 2022-02-15.pdf
 Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL40551_R2_AE_PER7552 SS 2022-02-15.pdf
 Created by Independent Third Party: Yes
40551.3 325 Series Gen 2 Casement Window (HVHZ) (Impact) 325 Series Gen 2 Casement Window (HVHZ) (Impact)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: See Installation Instructions and Evaluation Report for allowable design pressures, configurations, sizes, installations requirements and limits of use.
Installation Instructions
 FL40551_R2_II_CDW007 SS 2024-05-02.pdf
 Verified By: Hermes F. Norero 73778
 Created by Independent Third Party: Yes
Evaluation Reports
 FL40551_R2_AE_PER 9187 SS 2024-05-02.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: