| 4953.1 |
1.0 Nail Strip Panel 24GA |
1.0 Nail Strip Panel 24GA over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -59.75psf panel slot fastening @ 16"o.c. -101.0psf panel slot fastening @ 6-3/4"o.c. -153.5psf panel slot fastening: 6-3/4"o.c. @ 12"o.c. Panel Pan Fastening 6-3/4" @ 12"o.c. Not for use in HVHZ. Install per manufacturers details. |
Installation Instructions FL4953_R5_II_FL 4953 Spilker Metal Roofing -ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4953_R5_AE_FL 4953 Spilker Metal Roofing -ss.pdf Created by Independent Third Party: Yes |
|
|
| 4953.2 |
Snap Lock |
1.5 Snap Lock 24 Ga. over APA Rated Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -86.0 psf @ 24" o.c. -108.5 psf @ 12" o.c. -116.0 psf @ 6" o.c. Install per manufacturers details. 24GA Panel For use in HVHZ Zones.
|
Installation Instructions FL4953_R5_II_FL 4953 Spilker Metal Roofing -ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4953_R5_AE_FL 4953 Spilker Metal Roofing -ss.pdf Created by Independent Third Party: Yes |
|
|
| 4953.3 |
Snap Lock Aluminum |
1.5 Snap Lock 0.032 ALUM over 15/32" APA rated plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52psf Other: Aluminum 0.032 Panel-45psf@ 16"o.c. -52psf @ 6"o.c. Not for use in HVHZ. |
Installation Instructions FL4953_R5_II_FL 4953 Spilker Metal Roofing -ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL4953_R5_AE_FL 4953 Spilker Metal Roofing -ss.pdf Created by Independent Third Party: Yes |