| 6876.1 |
EHH-501X Hurricane Louver |
5" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35289 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL6876_R12_C_CAC_Load and Size Tables R25119.pdf FL6876_R12_C_CAC_UL Quality Assurance Contract 12-31-2027.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL6876_R12_II_EHH-501X Install Details - Clip Angle Mount.pdf FL6876_R12_II_EHH-501X Install Details - Continuous Angle Mount.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6876.2 |
ESD-435X Hurricane Louver |
4" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35289 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL6876_R12_C_CAC_Load and Size Tables R25119.pdf FL6876_R12_C_CAC_UL Quality Assurance Contract 12-31-2027.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL6876_R12_II_ESD-435X Install Details - Clip Angle Mount.pdf FL6876_R12_II_ESD-435X Install Details - Continuous Angle Mount.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 6876.3 |
ESD-635X Hurricane Louver |
6" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35289 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL6876_R12_C_CAC_Load and Size Tables R25119.pdf FL6876_R12_C_CAC_UL Quality Assurance Contract 12-31-2027.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL6876_R12_II_ESD-635X Install Details - Clip Angle Mount.pdf FL6876_R12_II_ESD-635X Install Details - Continuous Angle Mount.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |