| 24496.1 |
Aluminum Clad Casement |
Aluminum Clad Casement Single 36"x 84" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_436-H-105.53 CCL.pdf Quality Assurance Contract Expiration Date 03/06/2027 Installation Instructions FL24496_R3_II_Clad Csmt Operator 1W 36x84 CCL436-H-105_53 ESP025100P-2134.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.2 |
Aluminum Clad Casement |
Aluminum Clad Casement Arched Top Single 36"x 72" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-65 Other: Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_Sierra 436-H-105.65 CCL.pdf Quality Assurance Contract Expiration Date 10/28/2025 Installation Instructions FL24496_R3_II_Clad ARCH CA OP 36x72 CCL 436-H-105_65 TestESP016461P-1553.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.3 |
Clad Aspen 2.0 Casement |
Clad Aspen 2.0 Casement 2-Wide 76"x 78" (38"/38"x 78") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Span 78"; Trib width 38"; Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_429-H-560.30 CCL.pdf Quality Assurance Contract Expiration Date 11/08/2026 Installation Instructions FL24496_R3_II_429-H-560.30, .32, .33 C-AC2 Two-Wide Nail Fin Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.4 |
Clad Aspen 2.0 Casement |
Clad Aspen 2.0 Casement 3-Wide w/3-Wide Aspen 2.0 Casement Transom Above 108"x 120" (36"/36"/36"x 84" w/36"/36"/36"x 36" transom) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Span 108"; Trib width 60"; Requires 1/4" steel horizontal plate mull; Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_429-H-560.31 CCL.pdf Quality Assurance Contract Expiration Date 09/30/2026 Installation Instructions FL24496_R3_II_429-h-560-31 C- AC2 C- AT2 C- AC2P Three-Wide x Two-High Nail Fin Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.5 |
Clad Aspen 2.0 Casement |
Clad Aspen 2.0 Casement 2-Wide 76"x 96" (38"/38"x 96) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Span 96"; Trib width 38"; Requires 1/4" steel vertical plate mull; Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_429-H-560.32 CCL.pdf Quality Assurance Contract Expiration Date 11/08/2026 Installation Instructions FL24496_R3_II_429-H-560.30, .32, .33 C-AC2 Two-Wide Nail Fin Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.6 |
Clad Aspen 2.0 Casement |
Clad Aspen 2.0 Casement 2-Wide 72"x 84" (36"/36"x 84") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Span 84"; Trib width 36"; Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_429-H-560.33 CCL.pdf Quality Assurance Contract Expiration Date 09/30/2026 Installation Instructions FL24496_R3_II_429-H-560.30, .32, .33 C-AC2 Two-Wide Nail Fin Installation Instructions.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.7 |
H3 2.0 Casement |
H3 2.0 Casement w/H3 2.0 Direct Set Transom 120"x 108" (40"/40"/40"x 72" below 120"x 36") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Span 120"; Trib width 54"; Casement common mull; Requires 1/4" aluminum horizontal plate mull and mull installation clips; Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_Sierra 436-H-690.90 CCL (1).pdf Quality Assurance Contract Expiration Date 02/19/2026 Installation Instructions FL24496_R3_II_H3 2.0 Casement 3w under Direct Set 1w 120x108 CCL 436-H-660.90 ESP025931P-2191.3.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24496.8 |
Vinyl Casement |
Vinyl Casement 2-Wide with 2-Wide Transom 70"x 96" (36"/36"x 72" with 36"/36"x 24" transom) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Span 70.25"; Trib width 47.5"; Casement and transom common mull; Requires 2-piece aluminum interlocking horizontal mull; Complies with ASTM E1300 requirements. |
Certification Agency Certificate FL24496_R3_C_CAC_448-H-004.18 CCL.pdf Quality Assurance Contract Expiration Date 02/28/2027 Installation Instructions FL24496_R3_II_8000 Vinyl CA Op-Transom 2-W2-H 70X96 CCL 448-H-004_18 ESP025014P-2128.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |