| 24481.1 |
H3 2.0 Double Hung |
H3 2.0 Double Hung Oper/Oper/Picture 167"x 84" (48"/48"/72"x 84") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: Span 83.5"; Trib Width 59.5"; Tight mull; Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL24481_R4_C_CAC_Sierra436CCL__436-H-671.80[1].pdf Quality Assurance Contract Expiration Date 09/04/2027 Installation Instructions FL24481_R4_II_H3 2.0 DH op-op-pic 167x84 CCL 436-H-671.78_80 ESP026016P-2192.2 Rev A rev 10-23-2023.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24481.2 |
H3 2.0 Double Hung |
H3 2.0 Double Hung Oper/Oper/ Picture 167"x 84" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Span 83.5"; Trib width 59.5"; Tight mull; Requires installation clips; Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL24481_R4_C_CAC_Sierra436CCL 436-H-671.82.pdf Quality Assurance Contract Expiration Date 09/04/2027 Installation Instructions FL24481_R4_II_H3 2.0 DH op-op-pic 167x84 CCL 436-H-671.81_82 ESP026016P-2192.2 Rev A rev 10-20-2023.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24481.3 |
Monument Clad Double Hung |
Monument Clad Double Hung 2-Wide 99"x 97" (49"x 97") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: Span 96.63"; Trib width 49.32"; Structural aluminum nail fin; Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL24481_R4_C_CAC_Sierra436CCL 436-H-671.62.pdf Quality Assurance Contract Expiration Date 03/20/2030 Installation Instructions FL24481_R4_II_MNMNT DH OP 99x97 2-Wide CCL436-H-62 ESP016300P-1536.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24481.4 |
Monument Clad Double Hung |
Monument Clad Double Hung 2-Wide 75"x 77" (38"x 77") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL24481_R4_C_CAC_Sierra436CCL 436-H-671.64.pdf Quality Assurance Contract Expiration Date 03/20/2030 Installation Instructions FL24481_R4_II_MNMNT DH OP 2-W 75x77 CCL 436-H-615.64 D9790.01-602-44.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24481.5 |
Monument Clad Double Hung |
Monument Clad Double Hung-Single 45"x 97" |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL24481_R4_C_CAC_Sierra436CCL 436-H-671.77.pdf Quality Assurance Contract Expiration Date 03/20/2030 Installation Instructions FL24481_R4_II_MNMNT DH OP 45x97 CCL436-H-615.77 ESP016300P-1529.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 24481.6 |
Monument Clad Double Hung |
Monument Clad Double Hung 2-Wide 75"x 77" (37.31"x 76.63") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Span 76.63"; Trib width 37.31"; Complies with ASTM E1300 requirements.When products are installed in areas within 3,000 ft (914 m) of a saltwater coastline, fasteners shall comply with Section 1711.1.1 and connectors shall comply with Section 1711.1.2 as stated in FBC Edition 9, 2026. |
Certification Agency Certificate FL24481_R4_C_CAC_Sierra436CCL 436-H-671.79.pdf Quality Assurance Contract Expiration Date 03/20/2030 Installation Instructions FL24481_R4_II_MNMNT DH OP 75x77 2-Wide CCL436-H-615_79 ESP016205P-1530.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |