Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL28364-R1
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Bridger Steel
Address/Phone/Email 1558 Amsterdam Road
Belgrade, MT 59714
(460) 294-9725
garth.dailey@bridgersteel.com
 
Authorized Signature Garth Dailey
garth.dailey@bridgersteel.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E.
Florida License PE-88223
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 11/29/2023
Validated By Brian Jaks, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL28364_R1_COI_Letter of Certification- Bridger Steel_sealed.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E 15922005
FM 44711992
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/15/2020
Date Validated 12/21/2020
Date Pending FBC Approval 01/02/2021
Date Approved 02/09/2021
 
Summary of Products
FL # Model, Number or Name Description
28364.1 24 Ga. 7/8” Corrugated Roof Panel 24 Ga. 7/8” Corrugated Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-170.0psf
 Other: -55.0 psf at 5'-0" o.c. -126.9 psf at 2'-6" o.c -170.0 psf at 1'-0" o.c. Install per Manufacturer's installation details. Not for use in HVHZ Zones.
Installation Instructions
 FL28364_R1_II_FL28364.1 R1 24 Ga. 78 Corrugated Roof Panel_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28364_R1_AE_FL28364.1 R1 24 Ga. 78 Corrugated Roof Panel_sealed.pdf
 Created by Independent Third Party: Yes
28364.2 29 Ga. ¾” Corrugated Roof Panel 29 Ga. ¾” Corrugated Roof Panel over open framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-105.0psf
 Other: -56.0 psf at 3'-0" o.c. -84.0 psf at 2'-0" o.c. -105.0 psf at 1'-3" o.c. Install per Manufacturer's installation details. Not for use in HVHZ Zones.
Installation Instructions
 FL28364_R1_II_FL28364.2 R129 Ga. Corrugated Roof Panel_sealed.pdf
 Verified By: Johnathan E Green, P.E. 88223
 Created by Independent Third Party: Yes
Evaluation Reports
 FL28364_R1_AE_FL28364.2 R129 Ga. Corrugated Roof Panel_sealed.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex