| 14436.1 |
1- Envelope 2000® Rout & Return Wall System (RR) |
Exterior Wall System with MCM Panels and Interlocking Extrusions, Attached to Steel Studs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +53.3/-53.3 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacture's installation instructions as supplemental guide. |
Installation Instructions FL14436_R5_II_23-610.01_Env2000 ACM Wall RR on Steel Studs-ER.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14436_R5_AE_23-610.01_Env2000 ACM Wall RR on Steel Studs-ER.pdf Created by Independent Third Party: Yes |
|
|
| 14436.2 |
2- Envelope 2000® RainScreen Wall System (RS) |
Exterior Wall System with MCM Panels and Interlocking Extrusions, Attached to Steel Studs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +58/-58 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacture's installation instructions as supplemental guide. |
Installation Instructions FL14436_R5_II_23-610.02_Env2000 ACM Wall RS on Steel Studs-ER.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14436_R5_AE_23-610.02_Env2000 ACM Wall RS on Steel Studs-ER.pdf Created by Independent Third Party: Yes |
|
|
| 14436.3 |
3- Envelope 2000® Reveal Wall System (RV) |
Exterior Wall System with MCM Panels and Interlocking Extrusions, Attached to Steel Studs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacture's installation instructions as supplemental guide. |
Installation Instructions FL14436_R5_II_23-610.03_Env2000 ACM Wall RV on Steel Studs-ER.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14436_R5_AE_23-610.03_Env2000 ACM Wall RV on Steel Studs-ER.pdf Created by Independent Third Party: Yes |
|
|
| 14436.4 |
4- Envelope 2000® Deep Reveal Wall System (D-RV) |
Exterior Wall System with MCM Panels and Interlocking Extrusions, Adhered to Steel Hat Sub-Framing, and Attached to Steel Studs |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-30 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacture's installation instructions as supplemental guide. |
Installation Instructions FL14436_R5_II_23-610.04_Env2000 ACM Wall D-RV on Steel StudsER.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14436_R5_AE_23-610.04_Env2000 ACM Wall D-RV on Steel StudsER.pdf Created by Independent Third Party: Yes |