FL # FL21873-R3
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer The Door Store of America, Inc
Address/Phone/Email www.dsadoors.com
Raleigh, NC 27617
(919) 781-3200   Ext 106
guillermo@dsadoors.com
 
Authorized Signature Flores Guillermo
guillermo@dsadoors.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert J. Amoruso, PE
Florida License PE-49752
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL21873_R3_COI_CINo2483_Rev2_ss.pdf
FL21873_R3_COI_CINo2691_Rev1 - Complete Collection - NON-HVHZ_ss.pdf
FL21873_R3_COI_CINo2787_Rev1 - Complete Collection - HVHZ_ss.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E188613a
ASTM E199614a
ASTM E283-04(2012)2012
ASTM E3302014
ASTM E331-00(2009)2009
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL21873_R3_Equiv_EERNo2483_Rev2_ss.pdf
FL21873_R3_Equiv_EERNo2691_Rev1 - Complete Collection - NON-HVHZ_ss.pdf
FL21873_R3_Equiv_EERNo2787_Rev1 - Complete Collection - HVHZ_ss.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 11/16/2023
Date Validated 11/20/2023
Date Pending FBC Approval 11/26/2023
Date Approved 02/13/2024
Date Revised 09/11/2026
 
Summary of Products
FL # Model, Number or Name Description
21873.1 6/0 x 8/0 Tiffany Ashville Double ARCH top w/TDL 6/0 x 8/0 Tiffany Ashville Double ARCH top w/TDL
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed.
Installation Instructions
 FL21873_R3_II_DSA0005_RevB_Asheville-Double-ArchTop-TDL_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2483_Rev2_ss.pdf
 Created by Independent Third Party: Yes
21873.2 7/0 x 8/0 Double Full Lite/2 Panels 7/0 x 8/0 Double Full Lite/2 Panels
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed.
Installation Instructions
 FL21873_R3_II_DSA0003_RevB_ImpactDouble7080_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2483_Rev2_ss.pdf
 Created by Independent Third Party: Yes
21873.3 Alexandria 9 Lite Single Door with Sidelites and Transom Alexandria 9 Lite Single Door with Sidelites and Transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed.
Installation Instructions
 FL21873_R3_II_DSA0002_RevB_Alexandria-9Lite-Sidelites-Transom_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2483_Rev2_ss.pdf
 Created by Independent Third Party: Yes
21873.4 Complete Collection, Single and Double Doors, Inswing, Fully and Partially Glazed, HVHZ Complete Collection, Single and Double Doors, Inswing, Fully and Partially Glazed, HVHZ
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations.
Installation Instructions
 FL21873_R3_II_DSA0008_RevA_Complete Collection HVHZ - Inswing_ss.pdf
 Verified By: Robert J. Amoruso, PE FL No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2787_Rev1 - Complete Collection - HVHZ_ss.pdf
 Created by Independent Third Party: Yes
21873.5 Complete Collection, Single and Double Doors, Inswing, Fully Opaque. HVHZ Complete Collection, Single and Double Doors, Inswing, Fully Opaque. HVHZ
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations.
Installation Instructions
 FL21873_R3_II_DSA0010_RevA_Complete Collection HVHZ - Inswing_ss.pdf
 Verified By: Robert J. Amoruso, PE FL No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2787_Rev1 - Complete Collection - HVHZ_ss.pdf
 Created by Independent Third Party: Yes
21873.6 Complete Collection, Single and Double Doors, Inswing, Non-HVHZ Complete Collection, Single and Double Doors, Inswing, Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations.
Installation Instructions
 FL21873_R3_II_DSA0006_RevA_Complete Collection NON-HVHZ - Inswing_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2691_Rev1 - Complete Collection - NON-HVHZ_ss.pdf
 Created by Independent Third Party: Yes
21873.7 Complete Collection, Single and Double Doors, Outswing, Fully and Partially Glazed, HVHZ Complete Collection, Single and Double Doors, Outswing, Fully and Partially Glazed, HVHZ
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations.
Installation Instructions
 FL21873_R3_II_DSA0009_RevA_Complete Collection HVHZ - Outswing_ss.pdf
 Verified By: Robert J. Amoruso, PE FL No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2787_Rev1 - Complete Collection - HVHZ_ss.pdf
 Created by Independent Third Party: Yes
21873.8 Complete Collection, Single and Double Doors, Outswing, Fully Opaque, HVHZ Complete Collection, Single and Double Doors, Outswing, Fully Opaque, HVHZ
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations.
Installation Instructions
 FL21873_R3_II_DSA0011_RevA_Complete Collection HVHZ - Outswing_ss.pdf
 Verified By: Robert J. Amoruso, PE FL No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2787_Rev1 - Complete Collection - HVHZ_ss.pdf
 Created by Independent Third Party: Yes
21873.9 Complete Collection, Single and Double Doors, Outswing, Non-HVHZ Complete Collection, Single and Double Doors, Outswing, Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: See Performance Rating table on Sheet 1 of the Installation Instructions regarding Water Penetration Rating and Limitations.
Installation Instructions
 FL21873_R3_II_DSA0007_RevA_Complete Collection NON_HVHZ - Outswing_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2691_Rev1 - Complete Collection - NON-HVHZ_ss.pdf
 Created by Independent Third Party: Yes
21873.10 Double Full View Door with Full View Transom Double Full View Door with Full View Transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed.
Installation Instructions
 FL21873_R3_II_DSA0001_RevB_ImpactDouble6010DoorXX_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2483_Rev2_ss.pdf
 Created by Independent Third Party: Yes
21873.11 Full View Door with Full View Sidelites and Transom Full View Door with Full View Sidelites and Transom
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Product not tested for water penetration resistance. Therefore, the product must be used where water penetration is not required or where an overhang meeting the Requirements of the Current Edition of the FBC/FRC has been employed.
Installation Instructions
 FL21873_R3_II_DSA0004_RevB_ImpactSingleFullLite-Sidelites-Transom_ss.pdf
 Verified By: Robert J. Amoruso, PE FL PE No. 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL21873_R3_AE_PERNo2483_Rev2_ss.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex