FL # FL15858-R5
Application Type Affirmation
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Dean Steel Buildings, Inc
Address/Phone/Email 2929 Industrial Avenue
Fort Myers, FL 33901
(239) 334-1051
nandean@deansteelbuildings.com
 
Authorized Signature Nanette Dean
nandean@deansteelbuildings.com
 
Technical Representative Nanette Dean
Address/Phone/Email 2929 Industrial Avenue
Fort Myers, FL 33901
nandean@deansteelbuildings.com
 
Quality Assurance Representative Nanette Dean
Address/Phone/Email 2929 Industrial Avenue
Fort Myers, FL 33901
(239) 334-1051
nandean@deansteelbuildings.com
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Certification Mark or Listing
 
Certification Agency UL LLC
Validated By UL LLC
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
UL 5802006
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 12/18/2023
Date Validated 12/18/2023
Date Pending FBC Approval
Date Approved 12/30/2023
 
Summary of Products
FL # Model, Number or Name Description
15858.1 ProLock 24" wide, 24 ga min, steel panel over structural purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +52.5/-52.5
 Other: UL Construction No. 552. Design uplift pressure with supports @ 30". The required design wind loads shall be determined for each project. The maximum purlin spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by the Florida Building Code.
Certification Agency Certificate
 FL15858_R5_C_CAC_TJPV.R7706 Card.pdf
 FL15858_R5_C_CAC_ULReport.pdf
Quality Assurance Contract Expiration Date
 02/05/2028
Installation Instructions
 FL15858_R5_II_TGKX-552.pdf
 Verified By: Nanette Dean 45851
 Created by Independent Third Party: No
Evaluation Reports
 Created by Independent Third Party: 
15858.2 ProSeam 24" wide, 24 ga min, steel panel over structural purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +52.5/-52.5
 Other: UL Construction No. 205. Design uplift pressure with supports @ 30". The required design wind loads shall be determined for each project. The maximum purlin spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by the Florida Building Code.
Certification Agency Certificate
 FL15858_R5_C_CAC_TJPV.R7706 Card.pdf
 FL15858_R5_C_CAC_ULReport.pdf
Quality Assurance Contract Expiration Date
 02/05/2028
Installation Instructions
 FL15858_R5_II_TGKX-205.pdf
 Verified By: Nanette Dean 45851
 Created by Independent Third Party: No