| 10447.1 |
AHEP |
Adjustable Hip-End Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product is designed to be used as structural purlins in hip-end systems with step-down trusses and has not been evaluated for uplift resistance. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.2 |
DSC2R-SDS3, DSC2L-SDS3, DSC5R-SDS3, DSC5L-SDS3 |
Drag Strut Connectors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.3 |
GBC |
Gable Brace Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product is designed to resist lateral loads at the gable end wall and has not been evaluated for uplift resistance. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.4 |
HCP1.81, HCP2, HCP4 |
Hip Corner Plate |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If HCP1.81 or HCP2 are used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.5 |
HHRC2-2, HHRC42, HHRC42-2, HHRC4/1.81, HHRC44, HHRC5.25/3.25, HHRC5.37/3.12, HHRC66 |
Heavy Hip to Ridge Connectors |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.6 |
HRC1.81, HRC22 |
Hip Ridge Connector |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.7 |
LRU26, LRU28, LRU210, LRU212 |
Rafter Hanger |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If LRU26 with 10d nails is used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.8 |
LSU26, LSSU28, LSSU210 |
Light Slopeable/Skewable U Hanger
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.9 |
TBE4, TBE6 |
Truss Bearing Enhancer |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If using TBE4 to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.10 |
TC24, TC26, TC28 |
Truss Clip |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.11 |
THA29, THA213, THA218, THA218-2, THA222-2, THA413, THA418, THAC418, THA422, THAC422, THA426, THA422-2, THA426-2 |
Adjustable Truss Hanger |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If any THA model with minimum nailing or THA29 with maximum nailing is used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.12 |
THAI1.81/22, THAI2.06/22, THAI2.1/22, THAI222, THAI322, THAI3522, THAI422 |
Adjustable Truss Hanger Sized for I-Joists
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs.
|
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.13 |
THAL422, THAR422 |
Skewed Truss Hanger
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.14 |
THJA26, LTHJA26, LTHMA |
Multiple Truss Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: LTHJA26, LTHMA, and some applications of THJA26 provide less than 700 lbs of uplift resistance. If using these to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.15 |
THJM2-4-SDS3, THJM2-5-SDS3, THJU26, THJU26-W |
Multiple Truss Hangers |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: THJM2-4-SDS3, THJM2-5-SDS3, and THJU26-W installed with min. 2x4 hip & jack provide less than 700 lbs of uplift resistance. If using these to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.16 |
TSBR2-24 |
Truss Spacer-Restraint |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: This product is designed to provide temporary and permanent bracing for trusses and has not been evaluated for uplift resistance. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |
|
|
| 10447.17 |
VPA2, VPA25, VPA3, VPA35, VPA4 |
Variable Pitch Connectors
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2551.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2551.pdf |
|
|
| 10447.18 |
VTCR |
Valley Truss Clip |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: If used to resist wind uplift in HVHZ, provide supplemental connectors to achieve minimum 700 lbs. |
Installation Instructions FL10447_R8_II_ESR-2605.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10447_R8_AE_ESR-2605.pdf |