Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL10319-R6
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer ALL METAL ACQUISITIONS OF FL, LLC
Address/Phone/Email 2120 East Business 98
Panama City, FL 32401
(850) 769-9423
lindsay@allmetalroofing.com
 
Authorized Signature Phillip Santora
lindsay@allmetalroofing.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report LOCKE BOWDEN
Florida License PE-49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 03/23/2027
Validated By Diane Marotta, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL10319_R6_COI_FL 10319 ALL METAL ACQUISITIONS of NW Florida_17R_ss.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
FM 44711992
TAS 1001995
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/09/2020
Date Validated 12/18/2020
Date Pending FBC Approval 01/07/2021
Date Approved 02/09/2021
Date Revised 01/05/2024
 
Summary of Products
FL # Model, Number or Name Description
10319.1 1 3/4" Snap Lock 24Ga. Panel 24Ga. over 15/32" Plywood Non HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--123.5
 Other: -123.5psf@6"o.o. spacing, -108.5psf@24"o.c. spacing. Install per manufacturer details. For use in Non HVHZ.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.2 1 3/4" Snap Lock 26Ga. Panel 26Ga. Snap Lock over 15/32" APA plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--78.5
 Other: -78.5psf@6"o.c. spacing -63.5psf@24"o.c. spacing Install per manufacturers details. For use in Non HVHZ
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.3 1.5" Aluminum Mechanical Lock 1.5" Aluminum Mechanical Lock (0.032") over 15/32" APA Plywood Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-119.3psf
 Other: 16" Wide Panel: -76.8 psf @ 12"o.c. clip spacing. -89.3 psf @ 6" o.c. clip spacing. 12" Wide Panel: -119.3 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.4 1.5" Aluminum Mechanical Lock 1.5" Aluminum Mechanical (0.032") Lock 16" Wide over 22 Ga. Metal Deck Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-76.8PSF
 Other: 16" Wide Panel: -76.8 psf @ 12" o.c. clip spacing. -79.3 psf @ 6" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Terrence E. Wolfe, P.E. 44923
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.5 1.5" Mechanical Lock 24Ga. 1.5" Mechanical Lock 24 Ga. 16" Wide over 22 Ga. Metal Deck Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5 PSF
 Other: 16" Wide Panel: -52.5 PSF @ 24" o.c. clip spacing. -123.5 psf @ 6" o.c. clip spacing. Install per Manufacturers Installation Details. Not for use in HVHZ Zones.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.6 26Ga. Rib Roof Panel Rib 26 Ga. over 15/32" APA Plywood Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-69.25PSF
 Other: -69.25 psf @ 24" o.c. fasterner Pattern Type A. -146.0 psf 12" o.c. fastener pattern Type B. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.7 29 GA. RIB PANEL 29Ga over 1x4 @2 SYP wood purlins
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--183.5
 Other: -183.5psf fastening pattern 6"-3"-6"-3"-6"-3"-6"-3"@24"o.c. spacing. -108.5 fastening spacing 9"-9"-9"-9" Install per manufacturers details. For use in Non HVHZ
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.8 5V Crimp 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood HVHZ
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5PSF
 Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufactuers details. For use in HVHZ Zones.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Terrence E. Wolfe, P.E. 44923
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.9 7/8" Nail Strip 24 Ga. Roof Panel OVER 15/32" APA plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--101.5
 Other: -108.5psf 5 3/16"o.c. spacing -56.0psf 15 9/16" spacing Install per manufacturers details. For use in Non HVHZ
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.10 PBR Panel 26Ga PBR 26Ga. over 15/32" APA plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--154.75
 Other: -154.75psf fastening pattern 7"-5"-7"-5"-7"-5"@12"o.c. spacing. -59.25psf fastening pattern 12"-12"-12"@24" spacing. Install per manufacturers details.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.11 Rib 29 Ga. Rib 29 Ga. over 15/32" APA Plywood Non-HVHZ
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-71.75psf
 Other: -71.75 psf @ 24" o.c. fastener Pattern Type A. -146.0 psf @ 12" o.c. fastener Pattern Type B. Install per manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
10319.12 Rib 29Ga. 29Ga. Rib over 15/32" APA plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/--108.5
 Other: -108psf@ fastening pattern 6"-3"-6"-3"-6"-3"-6"-3" @24"o.c. spacing. -78.5psf fastener spacing 9"-9"-9"-9"@ 24"o.c. spacing. Install per manufacturers details. For use in Non HVHZ.
Installation Instructions
 FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Verified By: Locke Bowden, P.E. 49704
 Created by Independent Third Party: Yes
Evaluation Reports
 FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex