10319.1 |
1 3/4" Snap Lock 24Ga. Panel |
24Ga. over 15/32" Plywood Non HVHZ
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--123.5 Other: -123.5psf@6"o.o. spacing, -108.5psf@24"o.c. spacing. Install per manufacturer details. For use in Non HVHZ. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.2 |
1 3/4" Snap Lock 26Ga. Panel |
26Ga. Snap Lock over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--78.5 Other: -78.5psf@6"o.c. spacing
-63.5psf@24"o.c. spacing
Install per manufacturers details. For use in Non HVHZ |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.3 |
1.5" Aluminum Mechanical Lock |
1.5" Aluminum Mechanical Lock (0.032") over 15/32" APA Plywood Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-119.3psf Other: 16" Wide Panel: -76.8 psf @ 12"o.c. clip spacing. -89.3 psf @ 6" o.c. clip spacing. 12" Wide Panel: -119.3 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.4 |
1.5" Aluminum Mechanical Lock |
1.5" Aluminum Mechanical (0.032") Lock 16" Wide over 22 Ga. Metal Deck Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-76.8PSF Other: 16" Wide Panel: -76.8 psf @ 12" o.c. clip spacing. -79.3 psf @ 6" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.5 |
1.5" Mechanical Lock 24Ga. |
1.5" Mechanical Lock
24 Ga. 16" Wide over
22 Ga. Metal Deck Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 PSF Other: 16" Wide Panel: -52.5 PSF @ 24" o.c. clip spacing. -123.5 psf @ 6" o.c. clip spacing. Install per Manufacturers Installation Details. Not for use in HVHZ Zones. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.6 |
26Ga. Rib Roof Panel |
Rib 26 Ga. over 15/32" APA Plywood Non-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-69.25PSF Other: -69.25 psf @ 24" o.c. fasterner Pattern Type A. -146.0 psf 12" o.c. fastener pattern Type B. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.7 |
29 GA. RIB PANEL |
29Ga over 1x4 @2 SYP wood purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--183.5 Other: -183.5psf fastening pattern 6"-3"-6"-3"-6"-3"-6"-3"@24"o.c. spacing.
-108.5 fastening spacing 9"-9"-9"-9"
Install per manufacturers details.
For use in Non HVHZ |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.8 |
5V Crimp |
26 Ga. 5V Crimp Roof Panel over 15/32" Plywood HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufactuers details. For use in HVHZ Zones. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Terrence E. Wolfe, P.E. 44923 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.9 |
7/8" Nail Strip |
24 Ga. Roof Panel OVER 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--101.5 Other: -108.5psf 5 3/16"o.c. spacing
-56.0psf 15 9/16" spacing
Install per manufacturers details. For use in Non HVHZ |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.10 |
PBR Panel 26Ga |
PBR 26Ga. over 15/32" APA plywood.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--154.75 Other: -154.75psf fastening pattern 7"-5"-7"-5"-7"-5"@12"o.c. spacing.
-59.25psf fastening pattern 12"-12"-12"@24" spacing. Install per manufacturers details. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.11 |
Rib 29 Ga. |
Rib 29 Ga. over 15/32" APA Plywood Non-HVHZ
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71.75psf Other: -71.75 psf @ 24" o.c. fastener Pattern Type A. -146.0 psf @ 12" o.c. fastener Pattern Type B. Install per manufacturers details. Not for use in HVHZ Zones. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |
|
10319.12 |
Rib 29Ga. |
29Ga. Rib over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--108.5 Other: -108psf@ fastening pattern 6"-3"-6"-3"-6"-3"-6"-3" @24"o.c. spacing.
-78.5psf fastener spacing 9"-9"-9"-9"@ 24"o.c. spacing. Install per manufacturers details. For use in Non HVHZ. |
Installation Instructions FL10319_R6_II_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10319_R6_AE_FL10319_R6_II_All Metal Acquisitions -Details-ss.pdf Created by Independent Third Party: Yes |