| 5365.1 |
PBR Wall Panel |
26 Ga. PBR Wall Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +60.0PSF/-47.5PSF Other: +60.0 psf @ 5'-0" psf. -47.5 psf @ 5'-0" o.c. Panel is a thru-fastened structural wall panel capable of being installed over open framing in accordance with the specified load tables for wind pressures. NON HVHZ. Design engineer must evaluate the panel attachment to substrate for panel fastener pullout/pullover per AISI specifications. Install per manufacturer details. The use of this panel for shear diaphragm is outside the scope of this product approval.
Non-HVHZ
|
Installation Instructions FL5365_R6_II_SS FL 5365 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL5365_R6_AE_SS FL 5365 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |